A reduction coefficient is applied in usual design of multiple dowels type connections. The numbers of stiffeners in row is one of important factor to decide this coefficient. CLT drift pinned joint showed small orthotropy against in plane tensile load. Tensile tests of multiple drift pins joints were performed to evaluate the effect of array. Numbers of drift pins n in each specimen were same (n=12), but the arrangements were different (2 x 6, 3 x 4, 4 x 3, 6 x 2). Also the grain directions were parameters (0, 90 degrees). The reduction of initial stiffness and proportional limit load showed good agreement between theoretical prediction and experimental results.