Behaviours of Larch Glued Laminated Timber Beams Exposed to Standard Fire Heating During the Cooling Phase Study on Fire Performance of Structural Glued Laminated Timber Beams Part 1
Architectural Institute of Japan Structural System
Summary
Timber elements, which are different from other structural elements, have a characteristic problem in that the load bearing capacity decreases due to self-burning in the case of a fire, and this self-burning may continue after other fuel in the room has been exhausted. Therefore, the structural fire performance of timber elements should be clarified during not only the heating phase, but also the cooling phase. However, in examining the load bearing capacity of timber elements in a fire, few studies have considered the cooling phase. In the present paper, the fire performance of glued, laminated timber beams is discussed based on load-bearing fire tests that take the cooling phase into consideration.