Källsner and Girhammar [1] have presented a new plastic design method for wood-framed shear walls at ultimate limit state. This method allows the designer to calculate the load-carrying capacity of shear walls partially anchored, where the leading stud is not fully anchored against uplift. The parameters varied are the size of the washer and the orientation of the pith. The bottom rail was subjected to loading perpendicular to grain through two-sided sheathing. In this report the different set of series are presented. Five sets were conducted depending on the size of the washer and in each set the pith was placed upwards and downwards.