Preliminary CLT Fire Resistance Testing Report

https://research.thinkwood.com/en/permalink/catalogue377
Year of Publication
2012
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Organization
FPInnovations
Year of Publication
2012
Format
Report
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Topic
Fire
Keywords
Full Scale
Fire Resistance
Type X Gypsum Board
Thermocouples
Research Status
Complete
Summary
FPInnovations is involved in a large research project regarding CLT construction. One objective of this research is the creation of a design methodology for calculating the fire-resistance of CLT assemblies/construction. This methodology will foster the design of fire-safe buildings of wood or hybrid construction. In order to establish such calculation methods, a series of experimental tests has been undertaken. A total of eight full-scale CLT fire resistance tests have been conducted at the NRC fire laboratory where the panels were subject to the standard ULC S101 [1] fire exposure. The series consisted of three wall and five floor tests. Each test was unique using panels with a different number of plies and varying thicknesses. Some of the assemblies were protected using CGC Sheetrock® FireCode® Core Type X gypsum board while others were left unprotected.
Online Access
Free
Resource Link
Less detail