Assessment of Disproportionate Collapse for Multi Storey Cross Laminated Timber Buildings

https://research.thinkwood.com/en/permalink/catalogue1664
Year of Publication
2016
Topic
Connections
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Author
Mpidi Bita, Hercend
Currie, Neil
Tannert, Thomas
Year of Publication
2016
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Topic
Connections
Mechanical Properties
Keywords
Rotational Stiffness
Multi-Storey
Ductility
Loading
Conference
World Conference on Timber Engineering
Research Status
Complete
Notes
August 22-25, 2016, Vienna, Austria p. 3725-3733
Summary
This paper investigates the risk of disproportionate collapse following extreme loading events. The methodology mimics a sudden removal of a loadbearing wall of a twelve-storey CLT building. The ductility-demand from the dynamic simulation is checked against the ductility supplied by the structural components and their connections. The analyses focus on rotational stiffness (k) of the joints by considering three different sub-structural idealisations according to the required modelling details and the feasibility of model reductions. To resist the imposed dynamic forces, the required k-values may be too large to be practically achieved by means of off-the-shelf brackets and screw connections. Improved structural detailing as well as adequate thickness of structural elements need to be considered in order to reduce the probability of disproportionate collapse.
Online Access
Free
Resource Link
Less detail