Report of Testing Cross Laminated Timber Panels for Compliance with Can/ULC-S101 Standard Methods of Fire Endurance Tests of Building Construction and Materials: Loadbearing 3-Ply CLT Wall with 1 Layer of 5/8'' Type X Gypsum Board
Intertek Testing Services NA, Inc. (Intertek) has conducted testing for the Canadian Wood Council, on Cross-Laminated Timber Panels, to evaluate their fire resistance. Testing was conducted in accordance with the applicable requirements, and following the standard methods, of ASTM E119-14 Standard Test Methods for Fire Tests of Building Construction and Materials, OCtober 2014 Edition, and CAN/ULC-S101-07 Standard Methods of Fire Endurance Tests of Building Construction and Materials. This evaluation took place on November 12, 2014.