Earthquake-resisting performance of glulam frame structure was evaluated by shaking table tests on a specially designed glulam “double cross shape” specimen composed of slotted bolted connection (SBC) system. By the first vibration test using sinusoidal wave, the specimen survived until 80% level of input waves without damage. After renewing SBC system, the second vibration test was done on a same specimen using the JMA-Kobe NS waves having a maximum acceleration of 816gal. The specimen survived until 100% level of input without damage but failed by the panel-shear when 120% level was inputted. Earthquake-resisting performance of glulam moment-resisting joints composed of SBC system was considered as satisfactory enough for ductile joint system, but improvement of panelshear of glulam member itself was recognized as a future research need.