Cross-laminated timber (CLT) became a popular engineered wood product in recent years for highquality and innovative timber buildings. As for any building product, the fire behaviour of CLT panels requires careful evaluation in the design of such buildings. The adhesive used in the bond lines of CLT plays an important role in the fire design. However, currently, European standards do not provide a test method to assess the adhesive performance in CLT exposed to fire. This paper presents a series of fire tests performed with CLT panels glued with different adhesives. It is shown how the mass loss of the CLT panels in standard fire resistance tests can be used to assess the adhesive performance in CLT exposed to fire.