The objective of the test described in this report was to determine the fire endurance rating of a glulam load bearing beam to a column connection assembly, consisting of a glulam beam to column connection, and a CLT panel floor when exposed to the time/temperature conditions of ASTM E119-16a, Standard Test Methods for Fire Tests of Building Construction and Materials with a 24,360 lb load applied to the beam. Testing was conducted by Southwest Research Institute's Fire Technology Department, located in San Antonio, Texas, for The Framework Project, LLC, located in Portland, Oregon.