The airtightness of building must be measured for the evaluation of building energy performance. To make up the reference airtightness value of wooden houses built in Korea, blower door test was carried out in the 36 houses. And, during the test, the causes of air leakage were inspected simultaneously. The result showed that the average of ACH50((air change per hour at air pressure difference 50Pa) measured from light timber frame houses was 3.5 h-1 and the post-beam construction was 5.1h-1. And, insulation with form of foams was advantageous in ensuring building airtightness than glass fiber batt. And, values below 1.5 h-1 of ACH50, threshold for application of artificial air change equipment, had appeared after 2010s. Also, the values varied according to who managed the building construction field. Although only one measurement of CLT(cross laminated timber) residential building could be obtained in 2016, the result showed good airtightness of building with 0.7 h-1.