The seismic performance of a post-tensioned (PT) energy dissipating beam-to-column joint for glulam heavy timber structure is investigated in this paper. Such connection incorporates post-tensioned high-strength strand to provide self-centering capacity along with energy dissipating produced by a special steel cap, which is attached with the timber beam and also to prevent the end bearing failure of wood. The moment-rotation behaviour of the proposed posttensioned timber joint was investigated through a series of cyclic loading tests. The timber joint was loaded at the end of the beams to produce a moment at the joint, and the tests were conducted with three different post-tension forces in the steel strand. The hysteretic behaviour and self-centering capacity of the joint are evaluated based on the results from cyclic loading tests. The failure mechanism of the joint was illustrated through test observations, and the momentresisting capacity and energy dissipation of the joint were analysed with regard to various drift level. This research aims to provide possible solutions to minimize the residual deformation of heavy timber structure made of glulam in China.