The mechanical behaviour of timber-to-timber connections with internal panels of densified veneer wood (DVW) and fibre-reinforced polymer (FRP) dowels was experimentally assessed and a design method, based on EN 1995-1-1, was developed. Embedment tests on DVW plates and bending/shear tests on FRP dowels were performed to characterise these components, followed by full-scale tests of connections assembled with these materials. The results show that these connections exhibit a mechanical behaviour compatible with structural applications, regarding both load-carrying capacity and ductility. The proposed design model is based on EN 1995-1-1’s expressions for connections with dowel-type fasteners and gives good predictions of the experimental load-carrying capacities.