This paper investigates the risk of disproportionate collapse following extreme loading events. The methodology mimics a sudden removal of a loadbearing wall of a twelve-storey CLT building. The ductility-demand from the dynamic simulation is checked against the ductility supplied by the structural components and their connections...
This paper discusses the impact of the natural frequency of multi-storey timber structures, focusing on force-based seismic design. Simplified approaches to determine the frequency of light-frame and cross-laminated timber structures are investigated. How stiffness parameters for simple two-dimensional analysis models can be derived from the different contributions of deformation...
The present work aims to define horizontal joint dimension tolerances for newly proposed prefabricated façade systems for applications in tall cross laminated timber (CLT) buildings based on the compression perpendicular to grain characteristics of the component. This requires a thorough understanding of structural settlement under vertical...
This paper presents the first results of the flanksound project, a study promoted by Rotho Blaas srl regarding flanking transmission between CLT panels jointed with different connection systems. The vibration reduction index Kij is evaluated according to the EN ISO 10848 standard by measuring the velocity level difference between CLT...
The seismic behaviour of timber buildings is strongly related to the energy dissipation capacity of connections. According to Standard, since timber is characterized by a brittle failure when subjected to tensile or bending actions, the dissipative zones shall be located in joints and connections, whereas timber members themselves...
This paper deals with a certain type of C.L.T. (Cross Laminated Timber) construction, in a residential building in Fristad, Sweden. The objective is to study impact noise transmission, at the lower frequency range (10-200 Hz), where wooden dwellings perform inefficiently...
This paper investigates the seismic analysis of multi-story cross laminated timber (XLAM) buildings. The influence of different parameters such as wall geometry, vertical load level, friction and, most importantly, connection stiffness, strength and ductility is assessed. Linear and nonlinear finite element (FE) analyses are carried out on a...
The cross laminated timber (CLT) technology is nowadays a well-known construction system, which that can be applied to several typologies of residential and commercial buildings. However some critical issues exist which limit the full development of the CLT construction technology: problems in handling, difficulty in assembling...