A. Shop Drawings and Details for Tests
B. Sound and Impact Test Results Summary
C. Test 1: Sound and Impact Transmission Test - CLT
D. Test 2: Sound and Impact Transmission Test - Concrete Topping
E. Test 3a: Sound and Impact Transmission Test - Marmoleum
F. Test 3b: Sound and Impact Transmission Test - Marmoleum
G. Test 4: Sound and Impact Transmission Test - Carpet
H. Test 5a: Sound and Impact Transmission Test - Luxury Vinyl Plank
I. Test 5b: Sound and Impact Transmission Test - Luxury Vinyl Plank
J. Test 6: Sound and Impact Transmission Test - Mechanical Roof
Advanced Wood-Based Solutions for Mid-Rise and High-Rise Construction: In-Situ Testing of the Brock Commons 18-Storey Building for Vibration and Acoustic performances
Report is currently not available due to the redevelopment of FPInnovations' publications website.
Abstract
This report addresses serviceability issues of tall wood buildings focusing on their vibration and sound insulation performance. The sound insulation and vibration performance may not affect the building’s safety, but affects the occupants’ comfort and the proper operation of the buildings and the function of sensitive equipment...
Advanced Wood-Based Solutions for Mid-Rise and High-Rise Construction: In-Situ Testing of the Origine 13-Storey Building for Vibration and Acoustic Performances
Report is currently not available due to the redevelopment of FPInnovations' publications website.
Abstract
Serviceability performance studied covers three different performance attributes of a building. These attributes are 1) vibration of the whole building structure, 2) vibration of the floor system, typically in regards to motions in a localized area within the entire floor plate, and 3) sound insulation performance of the wall and floor assemblies...
The ambient movement of three modern multi-storey timber buildings has been measured and used to determine modal properties. This information, obtained by a simple, unobtrusive series of tests, can give insights into the structural performance of these f...
In this paper, the relations between the load-deformation property of the CLT connections and the seismic performance of the 3 story CLT construction are analytically discussed. The static and the dynamic properties of the CLT connections led each from t...
The paper presents a numerical study conducted on a seven storey cross-laminated (X-lam) buildings equipped with translational Tuned Mass Dampers (TMD’s), as a technique for reducing the notoriously high drifts and maximum seismic accelerations of thes...