Skip header and navigation

6 records – page 1 of 1.

Failure Analysis of CLT Shear Walls with Opening Subjected to Horizontal and Vertical Loads

https://research.thinkwood.com/en/permalink/catalogue1655
Year of Publication
2016
Topic
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Author
Motoi Yasumura
Kenji Kobayashi
Minoru Okabe
Year of Publication
2016
Country of Publication
Austria
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Topic
Mechanical Properties
Keywords
Opening
FEM
Horizontal Loading
Failure
Language
English
Conference
World Conference on Timber Engineering
Research Status
Complete
Notes
August 22-25, 2016, Vienna, Austria p. 3555-3562
Abstract
CLT wall panels having an opening were subjected to horizontal loading and the failure process of CLT around the opening was compared with the simulation by Finite Element Method. Three types of CLT wall panels of 3500mm length and 2700mm height had an opening of 1500mm length and 900mm to 2000mm height at the center of...
Online Access
Free
Resource Link
Less detail

Hybrid System of Unbonded Post-Tensioned CLT Panels and Light-Frame Wood Shear Walls

https://research.thinkwood.com/en/permalink/catalogue757
Year of Publication
2017
Topic
Design and Systems
Mechanical Properties
Seismic
Material
CLT (Cross-Laminated Timber)
Light Frame (Lumber+Panels)
Application
Shear Walls
Author
Tu Xuan Ho
Thang Dao
Sriram Aaleti
John van de Lindt
Douglas Rammer
Publisher
American Society of Civil Engineers
Year of Publication
2017
Country of Publication
United States
Format
Journal Article
Material
CLT (Cross-Laminated Timber)
Light Frame (Lumber+Panels)
Application
Shear Walls
Topic
Design and Systems
Mechanical Properties
Seismic
Keywords
Post-Tensioned
Cyclic Loadings
Dynamic Analysis
Numerical model
Language
English
Research Status
Complete
Series
Journal of Structural Engineering
Abstract
Cross-laminated timber (CLT) is a relatively new type of massive timber system that has shown to possess excellent mechanical properties and structural behavior in building construction. When post-tensioned with high-strength tendons, CLT panels perform ...
Online Access
Free
Resource Link
Less detail

Racking Resistance and Ductility of CLT Shear Walls Under Horizontal and Vertical Loads

https://research.thinkwood.com/en/permalink/catalogue457
Year of Publication
2014
Topic
Mechanical Properties
Connections
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Author
Motoi Yasumura
Yoshimasa Ito
Year of Publication
2014
Country of Publication
Canada
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Topic
Mechanical Properties
Connections
Keywords
Yield Load
Ultimate Load
Failure Modes
Joints
Hold-Down
Language
English
Conference
World Conference on Timber Engineering
Research Status
Complete
Notes
August 10-14, 2014, Quebec City, Canada
Abstract
This paper shows the racking test results of CLT shear walls with different failure modes. The failure modes of shear walls were designed by using reliability analysis considering the failure of the hold down connections at the bottom end of shear wall a...
Online Access
Free
Resource Link
Less detail

Real-Time Hybrid Seismic Simulation of a Three-Story Wood Building with an Integrated CLT-Lightframe System (CLT-LIFS)

https://research.thinkwood.com/en/permalink/catalogue1649
Year of Publication
2016
Topic
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
Light Frame (Lumber+Panels)
Application
Shear Walls
Author
Tu Nguyen
Thang Dao
Sriram Aaleti
John van de Lindt
Kenneth Fridley
Year of Publication
2016
Country of Publication
Austria
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Light Frame (Lumber+Panels)
Application
Shear Walls
Topic
Mechanical Properties
Keywords
Post-Tensioned
Reverse Cyclic Loading
Simulation
Language
English
Conference
World Conference on Timber Engineering
Research Status
Complete
Notes
August 22-25, 2016, Vienna, Austria p. 3479-3487
Abstract
This paper presents the results of a study whose objective was to investigate the behaviour of a hybrid wood shearwall system defined herein as a combination of traditional light-frame wood shear walls with post-tensioned rocking cross laminated timber (CLT). The post-tensioned CLT panels in the hybrid system offer both vertical and...
Online Access
Free
Resource Link
Less detail

Seismic Assessment of a Three-Story Wood Building with an Integrated CLT-Lightframe System using RTHS

https://research.thinkwood.com/en/permalink/catalogue1293
Year of Publication
2018
Topic
Mechanical Properties
Seismic
Material
CLT (Cross-Laminated Timber)
Light Frame (Lumber+Panels)
Application
Shear Walls

Strength Properties of CLT Composed of Sugi Laminations : (9) Small Scale CLT Shear Wall

https://research.thinkwood.com/en/permalink/catalogue984
Year of Publication
2013
Topic
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls

6 records – page 1 of 1.