Skip header and navigation

5 records – page 1 of 1.

Development and Evaluation of CLT Shear Wall Using Drift Pinned Joint

https://research.thinkwood.com/en/permalink/catalogue673
Year of Publication
2014
Topic
Connections
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Author
Nakashima, Shoichi
Kitamori, Akihisa
Komatsu, Kohei
Que, Zeli
Isoda, Hiroshi
Year of Publication
2014
Country of Publication
Canada
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Topic
Connections
Mechanical Properties
Keywords
Cedar
Shear Failure
Drift Pin Joint
Steel Connectors
Language
English
Conference
World Conference on Timber Engineering
Research Status
Complete
Notes
August 10-14, 2014, Quebec City, Canada
Abstract
The connectors for the CLT shear wall with drift pin joint were suggested. The wall composed of five layers Japanese cedar CLT, steel connectors and drift pins (diameter d = 16mm). The horizontal shear performances of the walls were evaluated by static e...
Online Access
Free
Resource Link
Less detail

Development of CLT Shear Frame Using Metal Plate Insert Connections

https://research.thinkwood.com/en/permalink/catalogue697
Year of Publication
2014
Topic
Connections
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Author
Kitamori, Akihisa
Nakashima, Shoichi
Isoda, Hiroshi
Year of Publication
2014
Country of Publication
Canada
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Topic
Connections
Mechanical Properties
Keywords
Failure Mode
Joints
Steel Plate
Strength
Steel Connectors
Language
English
Conference
World Conference on Timber Engineering
Research Status
Complete
Notes
August 10-14, 2014, Quebec City, Canada
Abstract
The purpose of this study is to develop a high strength leg joint for shear wall made of small size cross laminated timber panel in a simple system. The joint of CLT in which steel plate was inserted in the central slit and fixed by high strength bolt at...
Online Access
Free
Resource Link
Less detail

Lateral-Load Resistance of Cross-Laminated Timber Shear Walls

https://research.thinkwood.com/en/permalink/catalogue1238
Year of Publication
2017
Topic
Connections
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Author
Reynolds, Thomas
Foster, Robert
Bregulla, Julie
Chang, Wen-Shao
Harris, Richard
Ramage, Michael
Publisher
American Society of Civil Engineers
Year of Publication
2017
Country of Publication
United States
Format
Journal Article
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Topic
Connections
Mechanical Properties
Keywords
Vertical Load
Lateral Load
Pullout Tests
Steel Connectors
Offset-Yield Criterion
Language
English
Research Status
Complete
Series
Journal of Structural Engineering
Abstract
Cross-laminated timber shear wall systems are used as a lateral load resisting system in multistory timber buildings. Walls at each level typically bear directly on the floor panels below and are connected by nailed steel brackets. Design guidance for the lateral-load resistance of such systems is not well established and design...
Online Access
Free
Resource Link
Less detail

Prediction of Shear Performance on Cross Laminated Timber Wall with Wall to Wall Connections

https://research.thinkwood.com/en/permalink/catalogue1781
Year of Publication
2016
Topic
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Author
Oh, Jung-Kwon
Hong, Jung-Pyo
Kim, Chul-Ki
Pang, Sung-Jun
Lee, Hyeon-Jeong
Jang, Sung-Il
Park, Moon-Jae
Lee, Jun-Jae
Year of Publication
2016
Country of Publication
Austria
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Topic
Mechanical Properties
Keywords
Shear Performance
Failure Mode
Displacement
Peak Load
Model
Language
English
Conference
World Conference on Timber Engineering
Research Status
Complete
Notes
August 22-25, 2016, Vienna, Austria p. 5503-5510
Abstract
A cross-laminated timber (CLT) wall plays a role of resisting shear stress induced by lateral forces as well as resisting vertical load. Due to the press size, CLT panels have a limitation in its size. To minimize the initial investment, some glulam manufactures wanted to make a shear wall element with small-size CLT panels and panel-to-panel...
Online Access
Free
Resource Link
Less detail

Shear Behavior of Cross-Laminated Timber Wall Consisting of Small Panels

https://research.thinkwood.com/en/permalink/catalogue1411
Year of Publication
2017
Topic
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Author
Oh, Jung-Kwon
Hong, Jung-Pyo
Kim, Chul-Ki
Pang, Sung-Jun
Lee, Sang-Joon
Lee, Jun-Jae
Publisher
Springer Japan
Year of Publication
2017
Country of Publication
Japan
Format
Journal Article
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Topic
Mechanical Properties
Keywords
Kinematic Model
Peak Load
Displacement
Panel-to-Panel
Language
English
Research Status
Complete
Series
Journal of Wood Science
Online Access
Free
Resource Link
Less detail