Timber connections with steel dowel-type fasteners may fail in ductile or brittle ways. The design of this joints was traditionally focused on ductile failure, assuming that brittle failure could be avoided by means of geometrical limitations. However, recent studies demonstrated that these assumptions do not always guarantee ductile failure. A new design model for timber connections with small diameter dowel-type fasteners is provided in this paper. Its improved accuracy is demonstrated by analysing an extensive database of experimental tests and comparing its prediction accuracy to that of existing models.
This state-of-the-art report has been prepared within COST Action FP1402 Basis of structural timber design from research to standards, Working Group 3 Connections. The Action was established to create an expert network that is able to develop and establish the specific information needed for standardization committee decisions. Its main objective is to overcome the gap between broadly available scientific results and the specific information needed by standardization committees. This necessitates an expert network that links practice with research, i.e. technological developments with scientific background. COST presents the ideal basis to foster this type of joint effort. Chapter 8 Connections presents an integral part of Eurocode 5 and is in need of revision. This state-of-the-art report shall provide code writers with background information necessary for the development of the so-called Second Generation of the Eurocodes, now aimed to be produced in 2022.