Skip header and navigation

8 records – page 1 of 1.

Alternate Load-Path Analysis for Mid-Rise Mass-Timber Buildings

https://research.thinkwood.com/en/permalink/catalogue1233
Year of Publication
2018
Topic
Design and Systems
Seismic
Material
CLT (Cross-Laminated Timber)
Application
Floors
Wood Building Systems
Author
Mpidi Bita, Hercend
Tannert, Thomas
Organization
Structures Congress
Publisher
American Society of Civil Engineers
Year of Publication
2018
Country of Publication
United States
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Floors
Wood Building Systems
Topic
Design and Systems
Seismic
Keywords
Alternate Load-Path Analysis
Disproportionate Collapse
Lateral Loads
Language
English
Conference
Structures Conference 2018
Research Status
Complete
Notes
April 19–21, 2018, Fort Worth, Texas
Summary
This paper presents an investigation of possible disproportionate collapse for a nine-storey flat-plate timber building, designed for gravity and lateral loads. The alternate load-path analysis method is used to understand the structural response under various removal speeds. The loss of the corner and penultimate ground floor columns are the two cases selected to investigate the contribution of the cross-laminated timber (CLT) panels and their connections, towards disproportionate collapse prevention. The results show that the proposed building is safe for both cases, if the structural elements are removed at a speed slower than 1 sec. Disproportionate collapse is observed for sudden element loss, as quicker removal speed require higher moments resistance, especially at the longitudinal and transverse CLT floor-to-floor connections. The investigation also emphasises the need for strong and stiff column-to-column structural detailing as the magnitude of the vertical downward forces, at the location of the removed columns, increases for quicker removal.
Online Access
Payment Required
Resource Link
Less detail

Blast Testing of Loaded Cross-Laminated Timber Structures

https://research.thinkwood.com/en/permalink/catalogue1234
Year of Publication
2018
Topic
Mechanical Properties
Design and Systems
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Author
Weaver, Mark
Newberry, Charles
Podesto, Lisa
O’Laughlin, Casey
Organization
Structures Congress
Publisher
American Society of Civil Engineers
Year of Publication
2018
Country of Publication
United States
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Topic
Mechanical Properties
Design and Systems
Keywords
Blast Tests
Airblast Loads
Axial Load
Panels
Load Distribution
Quasi-Static
Language
English
Conference
Structures Conference 2018
Research Status
Complete
Notes
April 19–21, 2018, Fort Worth, Texas
Summary
Results from a series of blast tests performed in October 2016 on three two-story, single-bay cross-laminated timber (CLT) structures demonstrated the ability of CLT construction to resist airblast loads in a predictable fashion. These tests were performed on structures without superimposed load to limit inertial resistance. Subsequently, a follow-on series of tests was performed to investigate the response of axially-loaded CLT construction. Panels damaged during the preceding test were removed and replaced. Axial load was applied using precast concrete blocks to simulate the loaded condition of a five-story building at the first-floor front panel of the structures. These test structures were exposed to two shots: the first was designed to keep the structures within their respective elastic ranges while the second was designed to push the structures beyond their elastic limits. Reflected pressure and peak deflections were recorded at the front panels of the test structures to document the two-way panel load distribution behavior under a dynamic load event and the clearing of the shock wave. Prior to conducting the blast tests, a small number of tests were performed on a load tree test apparatus to aid in test planning by investigating the post-peak response of individual CLT panels of various lengths to quasi-static out-of-plane and axial loads applied simultaneously. This paper provides an overview of the results obtained from both the quasi-static and blast tests of axially-loaded CLT. Additionally, the paper compares CLT structure, component, and connection response across the suite of data. Conclusions are offered to assist engineers in the design of load bearing CLT construction exposed to airblast loads.
Online Access
Payment Required
Resource Link
Less detail

Capacity-Based Design for Cross-Laminated Timber Buildings

https://research.thinkwood.com/en/permalink/catalogue1255
Year of Publication
2017
Topic
Mechanical Properties
Connections
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Shear Walls
Author
Shahnewaz, Md
Tannert, Thomas
Alam, Shahria
Popovski, Marjan
Organization
Structures Congress
Publisher
American Society of Civil Engineers
Year of Publication
2017
Country of Publication
United States
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Shear Walls
Topic
Mechanical Properties
Connections
Keywords
In-Plane Stiffness
Strength
Non-Linear Springs
Finite Element Analysis
Hysteretic Behaviour
Cyclic Loading
Language
English
Conference
Structures Congress 2017
Research Status
Complete
Notes
April 6–8, 2017, Denver, Colorado
Summary
The use of cross-laminated timber (CLT) in residential and non-residential buildings is becoming increasingly popular in North America. While the 2016 supplement to the 2014 edition of the Canadian Standard for Engineering Design in Wood, CSAO86, provides provisions for CLT structures used in platform type applications, it does not provide guidance for the in-plane stiffness and strength of CLT shearwalls. The research presented in this paper investigated the in-plane stiffness and strength of CLT shearwalls with different connections for platform-type construction. Finite element analyses were conducted where the CLT panels were modelled as an orthotropic elastic material, and non-linear springs were used for the connections. The hysteretic behaviour of the connections under cyclic loading was calibrated from quasi-static tests; the full model of wall assemblies was calibrated using experimental tests on CLT shearwalls. A parametric study was conducted that evaluated the change of strength and stiffness of walls with the change in a number of connectors. Finally, a capacity-based design procedure is proposed that provides engineers with guidance for designing platform-type CLT buildings. The philosophy of the procedure is to design the CLT buildings such that all non-linear deformations and energy dissipation occurs in designated connections, while all other connections and the CLT panels are designed with sufficient over-strength to remain linear elastic.
Online Access
Payment Required
Resource Link
Less detail

Displacement Design Procedure for Cross Laminated Timber (CLT) Rocking Walls with Sacrificial Dampers

https://research.thinkwood.com/en/permalink/catalogue395
Year of Publication
2015
Topic
Design and Systems
Seismic
Material
CLT (Cross-Laminated Timber)
Application
Walls
Author
Gu, Mengzhe
Pang, Weichiang
Schiff, Scott
Organization
Structures Congress
Publisher
American Society of Civil Engineers
Year of Publication
2015
Country of Publication
United States
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Walls
Topic
Design and Systems
Seismic
Keywords
Energy Dissipation
Ductile Behavior
U-Shaped Flexural Plates
Self-centering Mechanism
Language
English
Conference
Structures Congress 2015
Research Status
Complete
Notes
April 23–25, 2015, Portland, Oregon, USA
Summary
This paper presents the preliminary design of a rocking Cross-laminated Timber (CLT) wall using a displacement-based design procedure. The CLT wall was designed to meet three performance expectations: immediate occupancy (IO), life safety (LS), and collapse prevention (CP). Each performance expectation is defined in terms of an inter-story drift limit with a predefined non-exceedance probability at a given hazard level. U-shape flexural plates were used to connect the vertical joint between the CLT panels to obtain a ductile behavior and adequate energy dissipation during seismic motion. A design method for ensuring self-centering mechanism is also presented.
Online Access
Payment Required
Resource Link
Less detail

Shear Connections with Self-Tapping-Screws for Cross-Laminated-Timber Panels

https://research.thinkwood.com/en/permalink/catalogue432
Year of Publication
2015
Topic
Connections
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Author
Hossain, Afrin
Lakshman, Ruthwik
Tannert, Thomas
Organization
Structures Congress
Publisher
American Society of Civil Engineers
Year of Publication
2015
Country of Publication
United States
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Topic
Connections
Mechanical Properties
Keywords
Ductility
Self-Tapping Screws
Stiffness
Strength
Vertical Shear Loading
Mid-Scale
Quasi-Static
Shear Tests
Language
English
Conference
Structures Congress 2015
Research Status
Complete
Notes
April 23–25, 2015, Portland, Oregon, USA
Summary
Cross-Laminated-Timber (CLT) is increasingly gaining popularity in residential and non-residential applications in North America. To use CLT as lateral load resisting system, individual panels need to be connected. In order to provide in-plane shear connections, CLT panels may be joined with a variety of options including the use of self-tapping-screws (STS) in surface splines and half-lap joints. Alternatively, STS can be installed at an angle to the plane allowing for simple butt joints and avoiding any machining. This study investigated the performance of CLT panel assemblies connected with STS under vertical shear loading. The three aforementioned options were applied to join 3ply and 5-ply CLT panels. A total of 60 mid-scale quasi-static shear tests were performed to determine and compare the connection performance in terms of strength, stiffness, and ductility. It was shown that – depending on the screw layout – either very stiff or very ductile joint performance can be achieved.
Online Access
Payment Required
Resource Link
Less detail

Structural Design, Approval, and Monitoring of a UBC Tall Wood Building

https://research.thinkwood.com/en/permalink/catalogue1252
Year of Publication
2017
Topic
Serviceability
Mechanical Properties
Design and Systems
Material
CLT (Cross-Laminated Timber)
Glulam (Glue-Laminated Timber)
Application
Hybrid Building Systems
Author
Tannert, Thomas
Moudgil, Ermanu
Organization
Structures Congress
Publisher
American Society of Civil Engineers
Year of Publication
2017
Country of Publication
United States
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Glulam (Glue-Laminated Timber)
Application
Hybrid Building Systems
Topic
Serviceability
Mechanical Properties
Design and Systems
Keywords
Vertical Shrinkage
Horizontal Building Vibration
Structural Performance
Concrete Core
Brock Commons
Language
English
Conference
Structures Congress 2017
Research Status
Complete
Notes
April 6–8, 2017, Denver, Colorado
Summary
In this paper, we discuss the structural design of one of the tallest timber-based hybrid buildings in the world: the 18 storey, 53 meter tall student residence on the campus of the University of British Columbia in Vancouver. The building is of hybrid construction: 17 storeys of mass wood construction on top of one storey of concrete construction. Two concrete cores containing vertical circulation provide the required lateral resistance. The timber system is comprised of cross-laminated timber panels, which are point supported on glued-laminated timber columns and steel connections between levels. In addition to providing more than 400 beds for students, the building will serve as an academic site to monitor and study its structural performance, specifically horizontal building vibration and vertical shrinkage considerations. We present the challenges relating to the approval process of the building and discuss building code compliance issues.
Online Access
Payment Required
Resource Link
Less detail

Tall Cross-Laminated Timber Building: Design and Performance Session WW300 Experimental and Modeling Studies on Wood Frame Buildings

https://research.thinkwood.com/en/permalink/catalogue618
Year of Publication
2014
Topic
Design and Systems
Seismic
Material
CLT (Cross-Laminated Timber)
Application
Walls
Wood Building Systems
Author
Dolan, Daniel
Bordry, Vincent
Pei, Shiling
van de Lindt, John
Organization
Structures Congress
Publisher
American Society of Civil Engineers
Year of Publication
2014
Country of Publication
United States
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Walls
Wood Building Systems
Topic
Design and Systems
Seismic
Keywords
Damping
Multi-Story
Ductility
Cost
Fire Resistance
Language
English
Conference
Structures Congress 2014
Research Status
Complete
Notes
April 3-5, 2014, Boston, Massachusetts, United States
Summary
Cross-laminated timber (CLT) is widely perceived as the most promising option for building high-rise wood structures due to its structural robustness and good fire resistance. While gravity load design of a tall CLT building is relatively easy to address because all CLT walls can be utilized as bearing walls, design for significant lateral loads (earthquake and wind) can be challenging due to the lack of ductility in current CLT construction methods that utilize wall panels with low aspect ratios (height to length). Keeping the wall panels at high aspect ratios can provide a more ductile response, but it will inevitably increase the material and labor costs associated with the structure. In this study, a solution to this dilemma is proposed by introducing damping and elastic restoring devices in a multi-story CLT building to achieve ductile response, while keeping the integrity of low aspect ratio walls to reduce the cost of construction and improve fire resistance. The design methodology for incorporating the response modification devices is proposed and the performance of the as-designed structure under seismic is evaluated.
Online Access
Payment Required
Resource Link
Less detail

Timber-Concrete Composites Using Flat-Plate Engineered Wood Products

https://research.thinkwood.com/en/permalink/catalogue616
Year of Publication
2015
Topic
Design and Systems
Connections
Material
CLT (Cross-Laminated Timber)
LSL (Laminated Strand Lumber)
LVL (Laminated Veneer Lumber)
Timber-Concrete Composite
Application
Floors
Author
Gerber, Adam
Tannert, Thomas
Organization
Structures Congress
Publisher
American Society of Civil Engineers
Year of Publication
2015
Country of Publication
United States
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
LSL (Laminated Strand Lumber)
LVL (Laminated Veneer Lumber)
Timber-Concrete Composite
Application
Floors
Topic
Design and Systems
Connections
Keywords
Concrete Topping
Mid-Scale
Push-Out Tests
Language
English
Conference
Structures Congress 2015
Research Status
Complete
Notes
April 23–25, 2015, Portland, Oregon, USA
Summary
Timber-Concrete Composite (TCC) systems have been employed as an efficient solution in medium span structural applications; their use remains largely confined to European countries. TCC systems are generally comprised of a timber and concrete element with a shear connection between. A large number of precedents for T-beam configurations exist; however, the growing availability of flat plate engineered wood products (EWPs) in North America has offered designers greater versatility in terms of floor plans and architectural expression in modern timber and hybrid structures. The opportunity exists to enhance the strength, stiffness, fire, and vibration performance of floors using these products by introducing a concrete topping, connected to the timber to form a composite. A research program at the University of British Columbia Vancouver investigates the performance of five different connector types (a post-installed screw system, cast-in screws, glued-in steel mesh, adhesive bonded, and mechanical interlocking) in three different EWPs (Cross-Laminated-Timber, Laminated-Veneer-Lumber, and Laminated-Strand-Lumber). Over 200 mid-scale push-out tests were performed in the first stage of experimental work to evaluate the connector performance and to optimize the design of subsequent vibration and bending testing of full-scale specimens, including specimens subjected to long-term loading.
Online Access
Payment Required
Resource Link
Less detail

8 records – page 1 of 1.