Skip header and navigation

2 records – page 1 of 1.

Blast Testing of Loaded Cross-Laminated Timber Structures

https://research.thinkwood.com/en/permalink/catalogue1234
Year of Publication
2018
Topic
Mechanical Properties
Design and Systems
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Author
Weaver, Mark
Newberry, Charles
Podesto, Lisa
O’Laughlin, Casey
Organization
Structures Congress
Publisher
American Society of Civil Engineers
Year of Publication
2018
Country of Publication
United States
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Topic
Mechanical Properties
Design and Systems
Keywords
Blast Tests
Airblast Loads
Axial Load
Panels
Load Distribution
Quasi-Static
Language
English
Conference
Structures Conference 2018
Research Status
Complete
Notes
April 19–21, 2018, Fort Worth, Texas
Summary
Results from a series of blast tests performed in October 2016 on three two-story, single-bay cross-laminated timber (CLT) structures demonstrated the ability of CLT construction to resist airblast loads in a predictable fashion. These tests were performed on structures without superimposed load to limit inertial resistance. Subsequently, a follow-on series of tests was performed to investigate the response of axially-loaded CLT construction. Panels damaged during the preceding test were removed and replaced. Axial load was applied using precast concrete blocks to simulate the loaded condition of a five-story building at the first-floor front panel of the structures. These test structures were exposed to two shots: the first was designed to keep the structures within their respective elastic ranges while the second was designed to push the structures beyond their elastic limits. Reflected pressure and peak deflections were recorded at the front panels of the test structures to document the two-way panel load distribution behavior under a dynamic load event and the clearing of the shock wave. Prior to conducting the blast tests, a small number of tests were performed on a load tree test apparatus to aid in test planning by investigating the post-peak response of individual CLT panels of various lengths to quasi-static out-of-plane and axial loads applied simultaneously. This paper provides an overview of the results obtained from both the quasi-static and blast tests of axially-loaded CLT. Additionally, the paper compares CLT structure, component, and connection response across the suite of data. Conclusions are offered to assist engineers in the design of load bearing CLT construction exposed to airblast loads.
Online Access
Payment Required
Resource Link
Less detail

Capacity-Based Design for Cross-Laminated Timber Buildings

https://research.thinkwood.com/en/permalink/catalogue1255
Year of Publication
2017
Topic
Mechanical Properties
Connections
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Shear Walls
Author
Shahnewaz, Md
Tannert, Thomas
Alam, Shahria
Popovski, Marjan
Organization
Structures Congress
Publisher
American Society of Civil Engineers
Year of Publication
2017
Country of Publication
United States
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Shear Walls
Topic
Mechanical Properties
Connections
Keywords
In-Plane Stiffness
Strength
Non-Linear Springs
Finite Element Analysis
Hysteretic Behaviour
Cyclic Loading
Language
English
Conference
Structures Congress 2017
Research Status
Complete
Notes
April 6–8, 2017, Denver, Colorado
Summary
The use of cross-laminated timber (CLT) in residential and non-residential buildings is becoming increasingly popular in North America. While the 2016 supplement to the 2014 edition of the Canadian Standard for Engineering Design in Wood, CSAO86, provides provisions for CLT structures used in platform type applications, it does not provide guidance for the in-plane stiffness and strength of CLT shearwalls. The research presented in this paper investigated the in-plane stiffness and strength of CLT shearwalls with different connections for platform-type construction. Finite element analyses were conducted where the CLT panels were modelled as an orthotropic elastic material, and non-linear springs were used for the connections. The hysteretic behaviour of the connections under cyclic loading was calibrated from quasi-static tests; the full model of wall assemblies was calibrated using experimental tests on CLT shearwalls. A parametric study was conducted that evaluated the change of strength and stiffness of walls with the change in a number of connectors. Finally, a capacity-based design procedure is proposed that provides engineers with guidance for designing platform-type CLT buildings. The philosophy of the procedure is to design the CLT buildings such that all non-linear deformations and energy dissipation occurs in designated connections, while all other connections and the CLT panels are designed with sufficient over-strength to remain linear elastic.
Online Access
Payment Required
Resource Link
Less detail