Skip header and navigation

7 records – page 1 of 1.

Chapter 10: Building Enclosure Design of Cross-Laminated Timber Construction

https://research.thinkwood.com/en/permalink/catalogue816
Year of Publication
2011
Topic
Serviceability
Moisture
Material
CLT (Cross-Laminated Timber)
Application
Walls
Author
Graham Finch
Dave Ricketts
Jieying Wang
Constance Thivierge
Paul Morris
Organization
FPInnovations
Year of Publication
2011
Country of Publication
Canada
Format
Book Section
Material
CLT (Cross-Laminated Timber)
Application
Walls
Topic
Serviceability
Moisture
Keywords
Airflow
Climate
Heat
Insulation
Moisture
North America
Language
English
Research Status
Complete
Series
CLT Handbook - Canadian Edition
Abstract
Cross-laminated timber (CLT) has become popular in Europe for the prefabricated construction of wall, roof and flooring elements. The use of CLT in North America is gaining interest in both the construction and wood industries. Several North American man...
Online Access
Free
Resource Link
Less detail

Comparison of Operational Energy Performance among Exterior Wall Systems for Mid-Rise Construction in Canada

https://research.thinkwood.com/en/permalink/catalogue355
Year of Publication
2015
Topic
Energy Performance
Material
CLT (Cross-Laminated Timber)
Light Frame (Lumber+Panels)
Application
Walls
Wood Building Systems
Author
Jieying Wang
Paul Morris
Organization
FPInnovations
Year of Publication
2015
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Light Frame (Lumber+Panels)
Application
Walls
Wood Building Systems
Topic
Energy Performance
Keywords
Mid-Rise
Canada
Exterior Walls
Energy Consumption
Residential
National Energy Code of Canada for Buildings
Climate
Steel-Stud Framing
Language
English
Research Status
Complete
Abstract
The largest source of energy consumption and greenhouse gas emissions in Canada and around the world is buildings. As a consequence, building designers are encouraged to adopt designs that reduce operational energy, through both increasingly stringent energy codes and voluntary green building programs that go beyond code requirements...
Online Access
Payment Required
Resource Link
Less detail

Durability of Mass Timber Structures: a Review of the Biological Risks

https://research.thinkwood.com/en/permalink/catalogue1838
Year of Publication
2018
Topic
Environmental Impact
Serviceability
Material
CLT (Cross-Laminated Timber)
Application
General Application

Evaluation of the Block Shear Resistance of Glulam Manufactured from Borate-Treated Lamina Wthout Planing After Treatment

https://research.thinkwood.com/en/permalink/catalogue367
Year of Publication
2015
Topic
Mechanical Properties
Material
Glulam (Glue-Laminated Timber)
Application
Wood Building Systems
Bridges and Spans
Author
Rod Stirling
Martin Feng
Paul Morris
Organization
FPInnovations
Year of Publication
2015
Country of Publication
Canada
Format
Report
Material
Glulam (Glue-Laminated Timber)
Application
Wood Building Systems
Bridges and Spans
Topic
Mechanical Properties
Keywords
Preservative
Borate
Canada
Shear Resistance
Polyurethane
Language
English
Research Status
Complete
Abstract
Effective preservative treatments for Canadian glulam products are needed to maintain markets for mass timber on building facades, access markets with significant termite hazards, and expand markets for wood bridges. For all three applications, borate-treatment...
Online Access
Payment Required
Resource Link
Less detail

Field Tests of Treated Thin-Lamina Glulam after Five Years of Exposure

https://research.thinkwood.com/en/permalink/catalogue370
Year of Publication
2015
Topic
Serviceability
Material
Glulam (Glue-Laminated Timber)
Application
Beams
General Application
Author
Paul Morris
Janet Ingram
Organization
FPInnovations
Year of Publication
2015
Country of Publication
Canada
Format
Report
Material
Glulam (Glue-Laminated Timber)
Application
Beams
General Application
Topic
Serviceability
Keywords
Cedar
Decay
Preservative
ACQ
Copper Azole
Fasteners
Language
English
Research Status
Complete
Abstract
Field tests of untreated and preservative-treated glulam beams in outdoor exposure, in ground contact and above ground, were inspected for decay after five years. Copper azole and ACQ-D-treated material was in excellent condition, while moderate to severe decay was present in untreated non-durable material...
Online Access
Payment Required
Resource Link
Less detail

Performance of Borate-Treated Glulam and LVL After Eight Years in an Accelerated Above-Ground Field Test

https://research.thinkwood.com/en/permalink/catalogue359
Year of Publication
2015
Topic
Serviceability
Material
Glulam (Glue-Laminated Timber)
LVL (Laminated Veneer Lumber)
Application
General Application
Author
Janet Ingram
Paul Morris
Organization
FPInnovations
Year of Publication
2015
Country of Publication
Canada
Format
Report
Material
Glulam (Glue-Laminated Timber)
LVL (Laminated Veneer Lumber)
Application
General Application
Topic
Serviceability
Keywords
Decay
Treated Wood
Borate
Language
English
Research Status
Complete
Abstract
Glulam and laminated veneer lumber protected by a combination of treatment with borate by two processes, and a film-forming coating, were exposed outdoors in an above-ground field test using a modified post and rail test design. After eight years’ exposure, early to moderate...
Online Access
Payment Required
Resource Link
Less detail

Performance of Preservative-Treated Glulam After Six Years in an Accelerated Above-Ground Field Test

https://research.thinkwood.com/en/permalink/catalogue360
Year of Publication
2015
Topic
Serviceability
Material
Glulam (Glue-Laminated Timber)
Application
General Application
Author
Janet Ingram
Paul Morris
Organization
FPInnovations
Year of Publication
2015
Country of Publication
Canada
Format
Report
Material
Glulam (Glue-Laminated Timber)
Application
General Application
Topic
Serviceability
Keywords
Decay
Preservative
Treated Wood
ACQ
CCA
Language
English
Research Status
Complete
Abstract
Glulam manufactured from laminating stock of three species pre-treated with ACQ-D or CA was exposed outdoors in an above-ground field test using a modified post and rail test design. After six years’ exposure, early to moderate decay was found in untreated test...
Online Access
Payment Required
Resource Link
Less detail