In this paper, the results of lateral loading tests on two types of CLT shear wall systems with an opening are summarized, one is the shear wall system with assembling narrow size CLT panels and another is that using one large size panel with an opening. 8 types, 13 specimens in all were tested. Load-displacement curves were obtained and characteristic values of shear performance were derived. As a result, the assembly system revealed higher ductility because of the ductility of connections between panels, while the rapture of large panel system was brittle though the shear capacity was higher than the assembly system.
The Japanese domestic forests have never been maintained enough, and it was a great fear that the multiple functions of the forest such as watershed conservation, the land conservation, and so on has been declined. The construction employing the cross laminates timber (CLT) panels was offered as a method of large scale building in domestic and foreign countries. However, the seismic design method of CLT panel construction has never completed. So, in order to consider the seismic design method, the shaking table tests and static lateral load tests were conducted to the modelized CLT panel construction.