The connectors for the CLT shear wall with drift pin joint were suggested. The wall composed of five layers Japanese cedar CLT, steel connectors and drift pins (diameter d = 16mm). The horizontal shear performances of the walls were evaluated by static e...
Earthquake-resisting performance of glulam frame structure was evaluated by shaking table tests on a specially designed glulam “double cross shape” specimen composed of slotted bolted connection (SBC) system. By the first vibration test using sinusoi...