Analysis of Cross-Laminated Timber Charring Rates Upon Exposure to Non-Standard Heating Conditions

https://research.thinkwood.com/en/permalink/catalogue136
Year of Publication
2015
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Author
Bartlett, Alastair
Hadden, Rory
Bisby, Luke
Law, Angus
Organization
Fire and Materials
Year of Publication
2015
Country of Publication
United States
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Topic
Fire
Keywords
Charring Rate
Heat Release Rate
Fire Resistance
Language
English
Conference
Fire and Materials 2015
Research Status
Complete
Notes
February 2-4, 2015, San Francisco, United States
Summary
The use of engineered timber products such as cross-laminated timber (CLT) is of increasing interest to architects and designers due to their desirable aesthetic, environmental, and structural properties. A key factor preventing widespread uptake of these materials is the uncertainty regarding their performance in fire. Currently, the predominant approach to quantifying the structural fire resistance of timber elements is the charring rate, which allows estimation of residual cross-section and hence strength. The charring rate is usually determined by testing timber specimens in a furnace by exposure to a ‘standard fire’. However, it is recognized that the resulting charring rates are not necessarily appropriate for non-standard fire exposures or for characterizing the structural response in a real timber building. The effect of heating rate on the charring rate of CLT samples is investigated. The charring rate resulting from three heating scenarios (constant, simulated ‘standard fire’ and quadratically increasing) was calculated using interpolation of in-depth temperature measurements during exposure to heating from a mobile array of radiant panels, or in a Fire Propagation Apparatus (FPA). Charring rate is shown to vary both spatially and temporally, and as a function of heating rate within the range 0.36–0.79 mm/min. The charring rate for tests carried out under simulated ‘standard fire’ exposures were shown to agree with the available literature, thus partially verifying the new testing approach; however under other heating scenarios the Eurocode charring rate guidance was found to be unconservative for some of the heat flux exposures in this study. A novel charring rate model is presented based on the experimental results. The potential implications of this study for structural fire resistance analysis and design of timber structures are discussed. The analysis demonstrates that heating rate, sample size and orientation, and test setup have significant effects on charring rate and the overall pyrolysis, and thus need to be further evaluated to further facilitate the use of structural timber in design.
Online Access
Free
Resource Link
Less detail

Fire Resistance of Wood Members with Directly Applied Protection

https://research.thinkwood.com/en/permalink/catalogue791
Year of Publication
2009
Topic
Fire
Material
Glulam (Glue-Laminated Timber)
LVL (Laminated Veneer Lumber)
Author
White, Robert
Organization
Fire and Materials
Publisher
Interscience Communications
Year of Publication
2009
Country of Publication
United States
Format
Conference Paper
Material
Glulam (Glue-Laminated Timber)
LVL (Laminated Veneer Lumber)
Topic
Fire
Keywords
Douglas-Fir
Type X Gypsum Board
US
Protection
Language
English
Conference
Fire and Materials 2009
Research Status
Complete
Notes
January 26-28, 2009, San Francisco, California, USA
Summary
Fire-resistive wood construction is achieved either by having the structural elements be part of fire-rated assemblies or by using elements of sufficient size that the elements themselves have the required fire-resistance ratings. For exposed structural wood elements, the ratings in the United States are calculated using either the T.T. Lie method or the National Design Specifications (NDS) Method. There is no widely accepted methodology in the United States to determine the fire-resistance rating of an individual structural wood element with the protective membrane directly applied to the exposed surfaces of the element. In these tests, we directly applied one or two layers of 16-mm thick fire-rated gypsum board or 13-mm thick southern pine plywood for the protective membrane to the wood element. The wood elements were Douglas-fir laminated veneer lumber (LVL) specimens and Douglas-fir gluedlaminated specimens that had previously been tested without any protective membrane. The methodology for the tension testing in the horizontal furnace was the same used in the earlier tests. The fire exposure was ASTM E 119. For the seven single-layer gypsum board specimens, the improvements ranged from 25 to 40 min. with an average value of 33 min. For the three double-layer specimens, the improvement in times ranged from 64 to 79 min. with an average value of 72 min. We concluded that times of 30 min. for a single layer of 16-mm Type X gypsum board and at least 60 min. for a double layer of 16-mm Type X gypsum board can be added to the fire rating of an unprotected structural wood element to obtain the rating of the protected element.
Online Access
Free
Resource Link