Skip header and navigation

6 records – page 1 of 1.

Behavior of Timber-Concrete Composite Beams with Two Types of Steel Dowel Connectors

https://research.thinkwood.com/en/permalink/catalogue1996
Year of Publication
2018
Topic
Connections
Mechanical Properties
Material
Timber-Concrete Composite
Application
Beams

Dowel Deformations in Multi-Dowel LVL-Connections Under Moment Loading

https://research.thinkwood.com/en/permalink/catalogue583
Year of Publication
2015
Topic
Connections
Mechanical Properties
Material
LVL (Laminated Veneer Lumber)
Author
Bader, Thomas
Schweigler, Michael
Hochreiner, Georg
Serrano, Erik
Enquist, Bertil
Dorn, Michael
Publisher
Taylor&Francis Online
Year of Publication
2015
Format
Journal Article
Material
LVL (Laminated Veneer Lumber)
Topic
Connections
Mechanical Properties
Keywords
Ductility
Bending Moment
Steel Dowels
Double-Shear
Steel-to-Timber
Four Point Bending Test
Research Status
Complete
Series
Wood Material Science & Engineering
Summary
The aim of the experimental study presented herein is the assessment and quantification of the behavior of individual dowels in multi-dowel connections loaded by a bending moment. For this purpose, doubleshear, steel-to-timber connections with nine steel dowels arranged in different patterns and with different dowel diameters were tested in 4-point bending. In order to achieve a ductile behavior with up to 7° relative rotation, the connections were partly reinforced with self-tapping screws. The reinforcement did not influence the global load-deformation behavior, neither for dowel diameters of 12 mm nor for 20 mm, as long as cracking was not decisive. The deformation of the individual dowels was studied by means of a non-contact deformation measurement system. Thus, the crushing deformation, i.e. the deformation at the steel plate, and the bending deformation of the dowels could be quantified. In case of 12 mm dowels, the bending deformation was larger than the crushing deformation, while it was smaller in case of 20 mm dowels. Moreover, dowels loaded parallel to the grain showed larger bending deformations than dowels loaded perpendicular to the grain. This indicates that the loading of the individual dowels in the connection differs, depending on their location.
Online Access
Free
Resource Link
Less detail

Load Distribution in Multi-Dowel Timber Connections Under Moment Loading - Integrative Evaluation of Multiscale Experiments

https://research.thinkwood.com/en/permalink/catalogue1499
Year of Publication
2016
Topic
Connections
Mechanical Properties
Material
LVL (Laminated Veneer Lumber)
Author
Bader, Thomas
Schweigler, Michael
Hochreiner, Georg
Eberhardsteiner, Josef
Year of Publication
2016
Format
Conference Paper
Material
LVL (Laminated Veneer Lumber)
Topic
Connections
Mechanical Properties
Keywords
Load Distribution
Steel Dowels
Steel Plates
Conference
World Conference on Timber Engineering
Research Status
Complete
Notes
August 22-25, 2016, Vienna, Austria p. 244-252
Summary
The load distribution in multi-dowel timber connections under bending moments was investigated by means of an integrative evaluation of a hierarchically organized test program, which encompassed component tests as well as single-dowel and multi-dowel connection tests. It was demonstrated that the anisotropic material behaviour of Laminated Veneer Lumber, and consequently of wood in general, leads to a non-uniform load distribution among the dowels, even for multi-dowel connections with a circular arrangement of dowels. Model predictions from this study highlight inefficiencies of the simplified calculation approach, based on the polar moment of inertia, i.e., based on isotropic theory. Loads of dowels loaded parallel to the grain were found to be underestimated by up to 50%. Through the hierarchically organized experimental campaign with full-field deformation measurement techniques, load distribution effects could be related to the orthotropic material behaviour of wood expressed in terms of load-to-grain angle dependent slip curves of single-dowel connections.
Online Access
Free
Resource Link
Less detail

Mode Cross-Over and Ductility of Dowelled LVL and CLT Connections under Monotonic and Cyclic Loading

https://research.thinkwood.com/en/permalink/catalogue1228
Year of Publication
2018
Topic
Mechanical Properties
Connections
Material
CLT (Cross-Laminated Timber)
LVL (Laminated Veneer Lumber)
Author
Ottenhaus, Lisa-Mareike
Li, Minghao
Smith, Tobias
Quenneville, Pierre
Publisher
American Society of Civil Engineers
Year of Publication
2018
Format
Journal Article
Material
CLT (Cross-Laminated Timber)
LVL (Laminated Veneer Lumber)
Topic
Mechanical Properties
Connections
Keywords
Steel Dowels
Steel Plates
Ductility
Brittle
Monotonic Loading
Cyclic Loading
Research Status
Complete
Series
Journal of Structural Engineering
Summary
This paper presents an experimental study on dowelled connections in Cross Laminated Timber (CLT) and Laminated Veneer Lumber (LVL) using 20 mm mild steel dowels and internal steel plates. Connections designed to fail in brittle row shear and group tear-out were tested under monotonic loading to assess the validity of analytical models from literature and code provisions. Connections designed to provide non-linearity before failure and thus produce ductility were tested under both monotonic and cyclic loading to study the influence of cyclic loading on ductility and the possibility of mode cross-over. It was found that cross layers in CLT improve ductility. Furthermore, mode cross-over from ductile response to brittle failure was observed in both CLT and LVL connections. Nevertheless, a good amount of ductility was achieved in all layouts (except the LVL connections designed for group tear-out failure) before cross-over to brittle failure occurred.
Online Access
Free
Resource Link
Less detail

Overstrength of Dowelled CLT Connections Under Monotonic and Cyclic Loading

https://research.thinkwood.com/en/permalink/catalogue1385
Year of Publication
2018
Topic
Connections
Mechanical Properties
Seismic
Material
CLT (Cross-Laminated Timber)
Author
Ottenhaus, Lisa-Mareike
Li, Minghao
Smith, Tobias
Quenneville, Pierre
Publisher
Springer Netherlands
Year of Publication
2018
Format
Journal Article
Material
CLT (Cross-Laminated Timber)
Topic
Connections
Mechanical Properties
Seismic
Keywords
Overstrength
Ductility
Three Point Bending Test
Fasteners
Yield Moment
Monotonic Loading
Cyclic Loading
Steel Dowels
Steel Plates
Research Status
Complete
Series
Bulletin of Earthquake Engineering
Summary
This paper presents an evaluation of overstrength based on an experimental study on dowelled connections in cross-laminated timber (CLT). Connection overstrength needs to be well understood in order to ensure that ductile system behaviour and energy dissipation can be achieved under seismic loading. Overstrength is defined as the difference between the code-based strength, using characteristic material strengths, and the 95th 4 percentile of the true strength distribution. Many aspects contribute to total connection overstrength, which makes its definition challenging. In this study, half-hole embedment tests were performed on CLT to establish embedment strength properties and three point bending tests were performed to determine the fastener yield moment. Different connection layouts, making use of mild steel dowels and an internal steel plate, were tested under monotonic and cyclic loading to evaluate theoretically determined overstrength values and study the influence of cyclic loading on overstrength. Experimental results were compared with strength predictions from code provisions and analytical models for ductile response under monotonic loading. It was found that cyclic loading does not significantly influence overstrength for connections that respond in a mixed-mode ductile way indicating that in future more expedient monotonic test campaigns could be used. This work also provides further experimental data and theoretical considerations necessary for the estimation of a generally applicable overstrength factor for dowelled CLT connections.
Online Access
Free
Resource Link
Less detail

Steel-to-Timber Joints of Beech-LVL with Very High Strength Steel Dowels

https://research.thinkwood.com/en/permalink/catalogue1502
Year of Publication
2016
Topic
Connections
Mechanical Properties
Material
LVL (Laminated Veneer Lumber)
Author
Misconel, Andrea
Ballerini, Marco
Van de Kuilen, Jan-Willem
Year of Publication
2016
Format
Conference Paper
Material
LVL (Laminated Veneer Lumber)
Topic
Connections
Mechanical Properties
Keywords
Beech
Steel-to-Timber
Joints
Steel Plates
Steel Dowels
Very High Strength Steel
Tensile Tests
Full Scale
Load Carrying Capacity
Ductility
Stiffness
Eurocode 5
Conference
World Conference on Timber Engineering
Research Status
Complete
Notes
August 22-25, 2016, Vienna, Austria p. 301-308
Summary
Double-shear steel-to-timber joints of beech laminated veneer lumber (LVL) with slotted-in steel plates using very high strength steel (VHSS) dowels have been investigated. Tensile tests on full-scale joints with one, two, three and six dowels have been carried out, using both VHSS and mild steel dowels. The goal of the research was to investigate the mechanical behaviour of joints of beech-LVL, with regard to load-carrying capacity (LCC), ductility, stiffness; and to find out whether the current design rules of Eurocode 5 are suitable for LVL and VHSS steels. Other examined aspects were the effect of multiple fasteners in a row and the influence of fastener steel grade. Tests showed higher values of joints with VHSS dowels, characterized generally by low scatter. The prediction ability of Eurocode 5 has been found to be inadequate and too conservative. A proposal for improvement is included.
Online Access
Free
Resource Link
Less detail

6 records – page 1 of 1.