Skip header and navigation

5 records – page 1 of 1.

Design of Post-Tensioned Timber Beams for Fire Resistance

https://research.thinkwood.com/en/permalink/catalogue4
Year of Publication
2012
Topic
Design and Systems
Fire
Material
LVL (Laminated Veneer Lumber)
Application
Beams
Author
Buchanan, Andrew
Abu, Anthony
Carradine, David
Moss, Peter
Spellman, Phillip
Year of Publication
2012
Country of Publication
Switzerland
Format
Conference Paper
Material
LVL (Laminated Veneer Lumber)
Application
Beams
Topic
Design and Systems
Fire
Keywords
Full Scale
Furnace Tests
Post-Tensioned
Box Beams
Vertical Loads
Failure
Language
English
Conference
International Conference on Structures in Fire
Research Status
Complete
Notes
June 6-8, 2012, Zurich, Switzerland
Online Access
Free
Resource Link
Less detail

The Fire Performance of Timber Floors in Multi-Storey Buildings

https://research.thinkwood.com/en/permalink/catalogue234
Year of Publication
2013
Topic
Fire
Design and Systems
Material
LVL (Laminated Veneer Lumber)
Timber-Concrete Composite
Application
Floors

Fireproof Tests and Heat Conduction Analyses for Development of 2-Hour Fire Resistant Structures

https://research.thinkwood.com/en/permalink/catalogue1778
Year of Publication
2016
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Application
Floors
Author
Kamikawa, Daisuke
Harada, Toshiro
Inada, Tatsuo
Kuratomi, Yoh
Shiozaki, Ikuo
Murata, Tadashi
Year of Publication
2016
Country of Publication
Austria
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Floors
Topic
Fire
Keywords
Furnace Fire Tests
Calcium Silicate Boards
Gypsum
Fire Resistance
Thickness
Heat Conduction Analysis
Numerical Model
Language
English
Conference
World Conference on Timber Engineering
Research Status
Complete
Notes
August 22-25, 2016, Vienna, Austria p. 5437-5444
Summary
Small furnace fire tests were conducted on CLT cladded with calcium silicate boards, gypsum boards, and combinations of the two. The difference in fire resistance when using different board types, combinations, and thicknesses was demonstrated. Some cross-sectional configurations had enough 2-hour fire resistance performance...
Online Access
Free
Resource Link
Less detail

Full-Scale Fire Tests of Post-Tensioned Timber Beams

https://research.thinkwood.com/en/permalink/catalogue257
Year of Publication
2012
Topic
Fire
Material
LVL (Laminated Veneer Lumber)
Application
Beams
Author
Spellman, Phillip
Carradine, David
Abu, Anthony
Moss, Peter
Buchanan, Andrew
Year of Publication
2012
Country of Publication
New Zealand
Format
Conference Paper
Material
LVL (Laminated Veneer Lumber)
Application
Beams
Topic
Fire
Keywords
Failure Mechanisms
Steel Anchorage
Full Scale
Furnace Tests
Post-Tensioned
Language
English
Conference
World Conference on Timber Engineering
Research Status
Complete
Notes
July 15-19, 2012, Auckland, New Zealand
Summary
This paper describes a series of full-scale furnace tests on loaded post tensioned LVL beams. Each beam was designed to exhibit a specific failure mechanism when exposed to the standard ISO834 fire. In addition to the beams a number of steel anchorage pr...
Online Access
Free
Resource Link
Less detail

Solutions for Mid-Rise Wood Construction: Intermediate-Scale Furnace Tests with Encapsulation Materials

https://research.thinkwood.com/en/permalink/catalogue353
Year of Publication
2014
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Light Frame (Lumber+Panels)
Application
Wood Building Systems