Skip header and navigation

2 records – page 1 of 1.

A Post-tensioned Cross-Laminated Timber Core for Buildings

https://research.thinkwood.com/en/permalink/catalogue2700
Year of Publication
2020
Topic
Connections
Mechanical Properties
Design and Systems
Material
CLT (Cross-Laminated Timber)
Application
Cores
Walls
Author
Znabei, Tigist
Year of Publication
2020
Format
Thesis
Material
CLT (Cross-Laminated Timber)
Application
Cores
Walls
Topic
Connections
Mechanical Properties
Design and Systems
Keywords
Prestress
Post-Tensioning
Bending
Shear Stiffness
Core Structure
Compressive Strength
Language
English
Research Status
Complete
Summary
This master thesis is on post-tensioning cross-laminated timber stability cores for multiple story buildings. When designing a CLT core, significantly larger core sections will be needed than when designing a stabilizing core in concrete. This is for one part due to the limited stiffness of the CLT compared to concrete. For another part it is due to the limited stiffness of connectors in CLT. Sliding and uplift can occur in connections in CLT loaded in tension and shear respectively. The CLT panels behave like rigid bodies, with most of the displacement occurring at the connections. In addition, cooperation between flange and web may be limited, depending on the stiffness of the corner connection and the occurrence of shear lag. Post-tensioning is suggested as a solution to diminish uplift and sliding in the connectors. In this way, with the same core section, a taller building may be realized compared to the non-post-tensioned case. In the thesis also the long-term effects on the prestress level is assessed, as estimating these effects is important for the safety of the system.This thesis adds to the body of knowledge on post-tensioned CLT structures. Firstly, previous studies on post-tensioned CLT focus on individual shear walls and on seismic design situations. This thesis explores how beneficial post-tensioning is from the perspective of serviceability limit state governed design. Furthermore, though post-tensioning as a prestressing method has been applied often in concrete structures, prestressing of CLT is a novel research subject. Especially the estimation of long-term force loss is a topic that still requires research. This thesis provides the designer with a straightforward calculation method (using python) for estimation of prestress force loss in the long-term.The research was carried out with a literature study and a case-study. The literature research comprised of studies on structural design with CLT loaded in-plane; the effective flange of a CLT core; stiffness of connections in CLT; prestressing of CLT; a design approach for post-tensioning; time dependent losses in post-tensioned CLT. The case study was based on a fictitious floorplan including a “minimal core”, and at expressing the benefit of post-tensioning in terms of height gain.The degree to which the flange and the web cooperate showed highly dependent on the connection between flange and web and the core height. In the case study, the effective flange width showed to depend highly on the height of the core and the stiffness of the connection between flange and web.In the case-study, without post-tensioning, approximately half of the displacements could be attributed to the connections. With post-tensioning, the uplift and sliding displacements in the horizontal joints was eliminated. Consequently, the attainable height was significantly increased: from 5 storeys in the un-post-tensioned case, to 8 storeys in the post-tensioned case. Long-term effects on the prestress loss were considerable. In the case-study, approximately 40% loss of post-tension force in the lifetime of the building was predicted and included in the design. Largest causeof force loss was due to changes of moisture content during construction. The remaining lateral displacements after post-tensioning were due to bending and shear.Post-tensioning of CLT cores is a powerful method for reducing lateral displacements in cases where uplift and sliding are dominant contributors to the lateral displacements. This is especially the case in light-weight buildings. Uplift and sliding displacements can be eliminated altogether with post-tensioning. The designer should realize that post-tensioning does not increase the bending and shear stiffness of the core. The thesis also concludes that with the post-tensioning of CLT walls, the compressive strength of the CLT in the so-called “compression-toe” might be exceeded. It is an important check in design. Furthermore, depending on the decision to re-tighten the rods at some point or not, the post-tension force loss should be calculated and included in finding the right prestress level. For this estimation of the moisture level of the CLT proved to be an important but difficult step. It is likely that the 40% force loss in the case-study is on the conservative side, since a large change in moisture content has been assumed. In practice, the moisture content can be measured on site. This can help verify the assumptions on the moisture content used in force loss calculations. This can help in assuring the structure is safe in the long-term.
Online Access
Free
Resource Link
Less detail

Verification of Seismic Resistant Performance of Developed Original Cross-Laminated Timber Core Structure Method by Shaking Table Experiment

https://research.thinkwood.com/en/permalink/catalogue2699
Year of Publication
2020
Topic
Seismic
Connections
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Author
Gunawan, Indra
Moritani, K
Isoda, Hiroshi
Mori, Takuro
Shinohara, M
Noda, T
Hosomi, R
Kurumada, Shinsuke
Makita, T
Publisher
IOP Publishing Ltd
Year of Publication
2020
Format
Journal Article
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Topic
Seismic
Connections
Keywords
Core Structure
Shaking Table
Joint
Wall-to-Foundation
Wall-to-Wall
Earthquake
Shear Force
Research Status
Complete
Series
IOP Conference Series: Materials Science and Engineering
Summary
In recent years, development of wood engineering is gradually increasing. Instead of using many wood columns, cross laminated timber is expected for constructing spacious open space building. Since cross-laminated timber has high rigidity and strength, cross-laminated timber is expected to be used as earthquake resistant wall or floor diaphragm that makes the span of building can be increased and the position of the wall can be adjusted openly. In order to optimize the performance of cross-laminated timber for open space building, original cross laminated timber core structure method was developed. In this paper, the development concept of original cross laminated timber core structure method will be explained. In this method, the joint connection for each element such as joint connection for wall-concrete foundation, wall-beam, and wall to hanging wall was also developed. The experiment to verify the strength and rigidity of each connection has been conducted and the result will be described. The shaking table experiment of 3-story open space building constructed by original cross laminated timber structure using varies earthquake waves was conducted. In this experiment natural period, shear force for each floor, story drift, and building response data is taken. The result shows the structure designed by original CLT core structure method is satisfy the requirement based on Japan cross-laminated panel structure regulation.
Online Access
Free
Resource Link
Less detail