Skip header and navigation

2 records – page 1 of 1.

Enhancing Thermal and Mechanical Performance of Engineered Wood Product Adhesives using Novel Fire Retardant Nanoclays

https://research.thinkwood.com/en/permalink/catalogue2810
Year of Publication
2021
Topic
Mechanical Properties
Fire
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Author
Oguzlu-Baldelli, Hale
Yu, Jason
Lee, George
Lam, Frank
Jiang, Feng
Organization
University of British Columbia
Year of Publication
2021
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Topic
Mechanical Properties
Fire
Keywords
Adhesive
PUR
Bond Strength
Halloysite
pMDI
Douglas-Fir
SPF
Bonding Shear Strength
Language
English
Research Status
Complete
Summary
One component PUR adhesive is widely used in engineered wood products applications, such as cross-laminated timber (CLT). However, the dramatic deterioration of PUR adhesive bond strength at elevated temperature can out tremendously threat for tall wood building, especially under fire. In this project, we are aiming to improving the bond strength of the PUR adhesive at high temperature by incorporating chemically modified halloysite to improve the poor interface between inorganic fillers and the polymer matrices. To improve the interaction with PUR (Loctite UR20 by Henkel®), the halloysite was chemically grafted with polymeric diphenylmethane diisocyanate (pMDI) (pMDI-H). The effect of adding pMDI modified halloysite to the PUR adhesives was investigated in terms of nanofiller dispersibility, thermal and mechanical properties of the pMDI-halloysite-PUR composite film, and the bonding shear strength of the glued Douglas fir and Spruce-Pine-Fir (SPF) shear blocks under different temperature. Significant improvement of the bond shear strength can be observed with the addition of 5 and 10% of pMDI-modified PUR adhesive, and the key research findings are summarized as below, a. pMDI can be successfully grafted onto hydroxylated halloysites to improve its dispersibility in one-component PUR adhesive; b. Addition of pMDI-H into PUR adhesive can lead to improved glass transition temperature and storage modulus. In contrast, no significant enhancement was observed in h-H added PUR films due to the poor dispersibility; c. Addition of up to 10% h-H and pMDI-H did not show significant change of the shear strength at 20 °C for both Douglas Fir and SPF; d. Significant enhancement of shear strength at elevated temperature (60-100 °C) can be observed for 5% and 10% pMDI-H modified PUR adhesive, showing 17% improvement for Douglas Fir and 27-37% for SPF.
Online Access
Free
Resource Link
Less detail

Evaluation of Adhesive Bond Strength of Two-Layer Asymmetric Cross-Laminated LSL Specimens

https://research.thinkwood.com/en/permalink/catalogue1548
Year of Publication
2016
Topic
Connections
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
LSL (Laminated Strand Lumber)
Author
Gong, Meng
Chui, Ying Hei
Li, Ling
Year of Publication
2016
Country of Publication
Austria
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
LSL (Laminated Strand Lumber)
Topic
Connections
Mechanical Properties
Keywords
Adhesives
Bond Strength
Short Span
Bending Tests
Two-Component Polyurethane
Polyvinyl Acetate
Language
English
Conference
World Conference on Timber Engineering
Research Status
Complete
Notes
August 22-25, 2016, Vienna, Austria p. 1185-1190
Summary
Massive timber panels (MTPs) has shown a great potential in construction of tall buildings. Evaluation of the face-bond strength of MTPs is of an interest to use of this kind of products. This study was aimed at developing an appropriate test procedure for evaluating the adhesive bond strength of cross-laminated laminated strand lumber (LSL). Short span bending tests were conducted on two-layer asymmetric cross-laminated LSL specimens, which were adhesively bonded using two-component polyurethane (PUR) and polyvinyl acetate (PVAc). For comparison, block shear specimens were tested as well. It was found that the 2-layer asymmetric cross-laminated specimen assembly under the short span bending could be used to differentiate between good and poor bond quality.
Online Access
Free
Resource Link
Less detail