Skip header and navigation

Refine Results By

1146 records – page 1 of 115.

Effects of Component Ratio of the Face and Core Laminae on Static Bending Strenght Performance of Three-Ply Cross-Laminated Wood Panels with Sugi (Cryptomeria Japonica)

https://research.thinkwood.com/en/permalink/catalogue1468
Year of Publication
2006
Topic
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
Author
Park, Han-Min
Fushitani, Masami
Publisher
Society of Wood Science and Technology
Year of Publication
2006
Country of Publication
United States
Format
Journal Article
Material
CLT (Cross-Laminated Timber)
Topic
Mechanical Properties
Keywords
Sugi
Lamina Thickness
Modulus of Elasticity
Modulus of Rupture
Proportional Limit Stress
Bending Strength
Language
English
Research Status
Complete
Series
Wood and Fiber Science
Summary
In order to improve the bending strength performance of three-ply laminated wood panels and use them as construction-grade panel materials, twelve types of three-ply cross-laminated wood panels whose percentages of core lamina thickness versus total lamina thickness were 33%, 50%, and 80% were made with sugi (Japanese cedar), and the effect of component ratio of the face and core laminae on their static bending strength performance was investigated. The moduli of elasticity (MOE), proportional limit stresses and moduli of rupture (MOR), perpendicular (C type) and parallel (C type) to the grain of face laminae markedly increased or decreased with increasing percentage of core lamina thickness. The percentages of core lamina thickness at which each strength property value of C type became equal to that of C type ranged from 65% to 80%. At each percentage of core lamina thickness, the MOE and proportional limit stress of C type were higher in C (45) specimens having perpendicular-direction lamina of 45° annual ring angle in the core than in C (90) specimens having perpendicular-direction lamina of 90° in the core, whereas there was little difference in MOR between C (45) specimens and C (90) specimens. For 45° specimens having the core lamina thickness from 60% to 70%, MOE as well as MOR parallel and perpendicular to the grain of face laminae exceeded the corresponding requirement values of structural plywood with 21.0-mm thickness specified in Japanese Agricultural Standards.
Online Access
Free
Resource Link
Less detail

Non Destructive Evaluation of Elastic Material Properties of Cross-Laminated Timber (CLT)

https://research.thinkwood.com/en/permalink/catalogue2315
Year of Publication
2008
Topic
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems

Prediction of Dynamic Response of a 7-Storey Massive XLam Wooden Building Tested on a Shaking Table

https://research.thinkwood.com/en/permalink/catalogue1885
Year of Publication
2010
Topic
Seismic
Material
CLT (Cross-Laminated Timber)

Lateral Load Resistance of Cross-Laminated Wood Panels

https://research.thinkwood.com/en/permalink/catalogue2150
Year of Publication
2010
Topic
Connections
Seismic
Material
CLT (Cross-Laminated Timber)
Application
Walls

Preliminary Assessment of Hygrothermal Performance of Cross-Laminated Timber Wall Assemblies Using Hygrothermal Models

https://research.thinkwood.com/en/permalink/catalogue2628
Year of Publication
2010
Topic
Moisture
Design and Systems
Serviceability
Material
CLT (Cross-Laminated Timber)
Light Frame (Lumber+Panels)
Application
Walls
Author
Wang, J.
Baldracchi, P.
Organization
FPInnovations
Year of Publication
2010
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Light Frame (Lumber+Panels)
Application
Walls
Topic
Moisture
Design and Systems
Serviceability
Keywords
Hygrothermal
Moisture Performance
Rainscreen
Language
English
Research Status
Complete
Summary
Preliminary simulation was carried out using hygIRC and WUFI, both 1-D hygrothermal models, to analyze moisture performance of rainscreened wood-frame walls and cross-laminated timber (CLT) walls for the climates in Vancouver and Calgary. The major results are as follows. In order to provide baseline knowledge, preliminary comparisons between hygIRC and WUFI were conducted to investigate the effects of climate data, wall orientations and rain intrusion on the performance of the rainscreened wood-frame walls based on Vancouver’s climate. hygIRC tended to produce almost constant moisture content (MC) of the plywood sheathing throughout a year but WUFI showed greater variations, particularly when the ventilation of the rainscreen cavity was neglected. Rainscreen cavity ventilation provided dramatic drying potentials for wall assemblies based on the WUFI simulation. hygIRC indicated that east-facing walls had the highest moisture load, but the differences between orientations seemed negligible in WUFI when the rainscreen cavity ventilation was taken into account. When 1% of wind-driven rain was simulated as an additional moisture load, hygIRC suggested that the rainscreen walls could not dry out in Vancouver, WUFI, however, indicated that they could dry to a safe MC level in the summer. The discrepancies in material property data between the two models and between different databases in WUFI (even for the same wood species) were found to be very large. In terms of wood sorption data, large differences existed at near-saturated RH levels. This is a result of using pressure-plate/membrane methods for measuring material equilibrium moisture content (EMC) under high RH conditions. The EMC of wood at near-100% RH conditions measured with these methods can be higher than 200%, suggesting wood in construction would decay without liquid water intrusion or severe vapour condensation. The pressure-plate/membrane methods also appeared to be highly species-dependent, and have higher EMC at a certain RH level for less permeable species, from which it is relatively difficult to remove water during the measurement. The hygrothermal simulation in this work suggested that such a species bias caused by testing methods could put impermeable species (most Canadian species) at a disadvantage to permeable species like southern pine during related durability design of building assemblies. In terms of using CLT for construction in Vancouver and Calgary, the WUFI simulations suggested that the use of less permeable materials such as EPS (expanded polystyrene insulation), XPS (extruded polystyrene insulation), self-adhered bituminous membrane and polyethylene in wall assemblies reduced the ability of the walls to dry. On the other hand, permeable assemblies such as those using relatively permeable insulation like semi-rigid mineral wool (rock wool) as exterior insulation, instead of less permeable exterior insulation materials, would help walls dry. The simulation also suggested that using CLT products with initially low MC would significantly reduce moisture-related risks, which indicated the importance of protecting CLT and avoiding wetting during transportation and construction. In addition, the simulation found that indoor relative humidity (RH) conditions generated by the indoor RH prediction models included in hygIRC and WUFI varied greatly under the same basic climate and building conditions. The intermediate method specified in ASHRAE Standard 160 P resulted in long periods of saturated RH conditions throughout a year for the Vancouver climate, which may not be representative of ordinary residential buildings in Vancouver. The simulation in this study is preliminary and exploratory. It would be arbitrary to recommend one model over the other based on this report or use the simulation results directly for CLT wall assembly design without consultation with building science specialists. However, this work revealed more opportunities for close collaborations between the wood science and the building science communities. More work should be carried out to develop appropriate testing methods and assemble material property data for hygrothermal simulation of wood-based building assemblies. Model improvement and field verification are also strongly recommended, particularly for new building systems such as CLT constructions.
Online Access
Free
Resource Link
Less detail

Manufacturing Cross-Laminated Timber (CLT): Technological and Economic Analysis

https://research.thinkwood.com/en/permalink/catalogue2636
Year of Publication
2010
Topic
Cost
Design and Systems
Material
CLT (Cross-Laminated Timber)
Author
Julien, F.
Organization
FPInnovations
Year of Publication
2010
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Topic
Cost
Design and Systems
Keywords
Manufacturing
Economic Analysis
Language
English
Research Status
Complete
Online Access
Free
Resource Link
Less detail

Displacement-Based Seismic Design of Timber Structures

https://research.thinkwood.com/en/permalink/catalogue1891
Year of Publication
2011
Topic
Design and Systems
Seismic
Material
CLT (Cross-Laminated Timber)
Glulam (Glue-Laminated Timber)
LVL (Laminated Veneer Lumber)
Other Materials
Application
Wood Building Systems
Walls
Floors
Beams
Columns
Frames

Block Shear Testing of CLT Panels: An Exploratory Study

https://research.thinkwood.com/en/permalink/catalogue2624
Year of Publication
2011
Topic
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
Author
Casilla, Romulo
Pirvu, Ciprian
Wang, Brad
Lum, Conroy
Organization
FPInnovations
Year of Publication
2011
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Topic
Mechanical Properties
Keywords
Adhesive
Block Shear Test
Failure
Language
English
Research Status
Complete
Summary
A study was conducted with the primary objective of examining the efficacy of a standard block shear test method to assess the bond quality of cross-laminated timber (CLT) products. The secondary objective was to examine the effect of pressure and adhesive type on the block shear properties of CLT panels. The wood material used for the CLT samples was Select grade nominal 25 x 152-mm (1 x 6-inch) Hem-Fir. Three adhesive types were evaluated under two test conditions: dry and vacuum-pressure-dry (VPD), the latter as described in CSA standard O112.10. Shear strength and wood failure were evaluated for each test condition. Among the four properties evaluated (dry and VPD shear strength, and dry and VPD wood failure), only the VPD wood failure showed consistency in assessing the bond quality of the CLT panels in terms of the factors (pressure and adhesive type) evaluated. Adhesive type had a strong effect on VPD wood failure. The different performance levels of the three adhesives were useful in providing insights into how the VPD block shear wood failure test responds to significant changes in CLT manufacturing parameters. The pressure used in fabricating the CLT panels showed a strong effect on VPD wood failure as demonstrated for one of the adhesives. VPD wood failure decreased with decreasing pressure. Although dry shear wood failure was able to detect the effect of pressure, it failed to detect the effect of adhesive type on the bond quality of the CLT panels. These results provide support as to the effectiveness of the VPD block shear wood failure test in assessing the bond quality of CLT panels. The VPD conditioning treatment was able to identify poor bondline manufacturing conditions by observed changes in the mode of failure, which is also considered an indication of wood-adhesive bond durability. These results corroborate those obtained from the delamination test conducted in a previous study (Casilla et al. 2011). Along with the delamination test proposed in an earlier report, the VPD block shear wood failure can be used to assess the CLT bond quality. Although promising, more testing is needed to assess whether the VPD block shear wood failure can be used in lieu of the delamination test. The other properties studied (shear strength and dry wood failure), however, were not found to be useful in consistently assessing bond line manufacturing quality.
Online Access
Free
Resource Link
Less detail

Checking in CLT Panels: An Exploratory Study

https://research.thinkwood.com/en/permalink/catalogue2625
Year of Publication
2011
Topic
Moisture
Material
CLT (Cross-Laminated Timber)
Author
Casilla, Romulo
Lum, Conroy
Pirvu, Ciprian
Wang, Brad
Organization
FPInnovations
Year of Publication
2011
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Topic
Moisture
Keywords
Panels
Testing Methods
Surface Checks
Moisture Content
Gaps
Language
English
Research Status
Complete
Summary
A study was conducted with the primary objective of gathering information for the development of a protocol for evaluating the surface quality of cross-laminated timber (CLT) products. The secondary objectives were to examine the effect of moisture content (MC) reduction on the development of surface checks and gaps, and find ways of minimizing the checking problems in CLT panels. The wood materials used for the CLT samples were rough-sawn Select grade Hem-Fir boards 25 x 152 mm (1 x 6 inches). Polyurethane was the adhesive used. The development of checks and gaps were evaluated after drying at two temperature levels at ambient relative humidity (RH). The checks and gaps, as a result of drying to 6% to 10% MC from an initial MC of 13%, occurred randomly depending upon the characteristics of the wood and the manner in which the outer laminas were laid up in the panel. Suggestions are made for minimizing checking and gap problems in CLT panels. The checks and gaps close when the panels are exposed to higher humidity. Guidelines were proposed for the development of a protocol for classifying CLT panels into appearance grades in terms of the severity of checks and gaps. The grades can be based on the estimated dimensions of the checks and gaps, their frequency, and the number of laminas in which they appear.
Online Access
Free
Resource Link
Less detail

Delamination Testing of CLT Panels: An Exploratory Study

https://research.thinkwood.com/en/permalink/catalogue2626
Year of Publication
2011
Topic
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
Author
Casilla, Romulo
Pirvu, Ciprian
Wang, Brad
Organization
FPInnovations
Year of Publication
2011
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Topic
Mechanical Properties
Keywords
Adhesive
Bond Quality
Delamination Test
Strength
Language
English
Research Status
Complete
Summary
A study was conducted with the primary objective of examining the efficacy of delamination test using cylindrical core specimens to assess the bond quality of cross laminated timber (CLT) products. A prototype coring drill bit was fabricated to prepare a cylindrical-shaped specimen, the height of which corresponds to the full thickness of the CLT panel. A secondary objective was to examine the effect of pressure, adhesive type, number of plies, and specimen shape on the delamination resistance of CLT panels. The wood material used for the CLT samples was Select grade nominal 1 x 6-inch Hem-Fir boards. Examples of three adhesive types were evaluated, which were designated as A, B, and C. The delamination tests used were as described in CAN / CSA O122-06 and EN 302-2. Cylindrical specimen extracted as core was found satisfactory as a test specimen type for use in delamination testing of CLT product. Its efficacy was comparable to that of a square cross-section specimen. The former is recommended as it can be extracted from thicker panels and from any location in the panel. It would also be more convenient to plug the round hole. Adhesive type had a strong effect on delamination resistance based on the two delamination tests used. Adhesive A exhibited the greatest delamination resistance, followed in decreasing order, by adhesives C and B. It should be noted that no effort was made to find the optimum CLT manufacturing parameters for each type of adhesive. Therefore the relative rankings of the adhesives tested may not be representative. However, for the purposes of this study, the different performance levels from the three adhesives are useful in providing insight into how the proposed delamination test responds to significant changes in CLT manufacturing parameters. Pressure used in fabricating the CLT panel showed a strong effect on delamination resistance as demonstrated for one of the adhesives. Delamination resistance decreased with decreasing pressure. The effect of the number of plies in the CLT panel was dependent upon the type of adhesive, and this was probably related to the adhesive’s assembly time characteristic. These results provide support as to the effectiveness of delamination test in assessing the moisture durability of CLT panels. It was able to differentiate the performance in delamination resistance among different types of adhesives, and able to detect the effect of manufacturing parameters such as pressure and increased number of plies in CLT construction. The test procedure described in CAN / CSA O122-06 appears to be reasonable in the delamination resistance assessment of CLT panels for qualification and quality control testing. Based on the results of the study along with some background information and guidelines, delamination requirements for CLT panels are proposed. The permitted delamination values are greater than those currently specified for laminated and fingerjoined lumber products. This is in recognition of the higher bond line stresses when bonded perpendicular laminations (i.e. CLT) are exposed to the delamination wetting and drying cycles, as opposed to parallel laminations (i.e. glulam or fingerjoints).
Online Access
Free
Resource Link
Less detail