This paper describes experiments conducted to develop a resilient lateral force resisting wall system that combines cross-laminated timber (CLT) panels with vertical post-tensioning (PT) to provide post-event re-centering. Supplemental mild steel U-shaped flexural plate devices (UFPs) are intended to yield under cyclic loading while the PT...