Skip header and navigation

Refine Results By

10 records – page 1 of 1.

Accommodating Movement in High-Rise Wood-Frame Building Construction

https://research.thinkwood.com/en/permalink/catalogue1875
Year of Publication
2011
Topic
Design and Systems
Connections
Material
Steel-Timber Composite
Other Materials
LVL (Laminated Veneer Lumber)
Application
Wood Building Systems
General Application
Floors
Walls

Acoustics: Sound Insulation in Mid-Rise Wood Buildings

https://research.thinkwood.com/en/permalink/catalogue37
Year of Publication
2014
Topic
Acoustics and Vibration
Material
CLT (Cross-Laminated Timber)
Light Frame (Lumber+Panels)
Application
Floors
Walls

Acoustics Summary: Sound Insulation in Mid-Rise Wood Building

https://research.thinkwood.com/en/permalink/catalogue750
Year of Publication
2014
Topic
Acoustics and Vibration
Design and Systems
Material
CLT (Cross-Laminated Timber)
Light Frame (Lumber+Panels)
Application
Wood Building Systems

Acoustic Testing and Wood Supply for Framework Office Building in Portland, OR

https://research.thinkwood.com/en/permalink/catalogue1830
Year of Publication
2017
Topic
Acoustics and Vibration
Material
CLT (Cross-Laminated Timber)
Application
Floors
Ceilings
Walls
Roofs
Wood Building Systems
Organization
ARUP
StructureCraft
InterTek
Year of Publication
2017
Country of Publication
United States
Format
Report
Material
CLT (Cross-Laminated Timber)
Application
Floors
Ceilings
Walls
Roofs
Wood Building Systems
Topic
Acoustics and Vibration
Keywords
Sound Transmission
Impact Noise Transmission
Concrete Topping
Language
English
Research Status
Complete
Series
Framework: An Urban + Rural Design
Summary
A. Shop Drawings and Details for Tests B. Sound and Impact Test Results Summary C. Test 1: Sound and Impact Transmission Test - CLT D. Test 2: Sound and Impact Transmission Test - Concrete Topping E. Test 3a: Sound and Impact Transmission Test - Marmoleum F. Test 3b: Sound and Impact Transmission Test - Marmoleum G. Test 4: Sound and Impact Transmission Test - Carpet H. Test 5a: Sound and Impact Transmission Test - Luxury Vinyl Plank I. Test 5b: Sound and Impact Transmission Test - Luxury Vinyl Plank J. Test 6: Sound and Impact Transmission Test - Mechanical Roof
Online Access
Free
Resource Link
Less detail

Advanced Topics in Seismic Analysis and Design of Mid-Rise Wood-Frame Structures

https://research.thinkwood.com/en/permalink/catalogue1773
Year of Publication
2016
Topic
Design and Systems
Material
Light Frame (Lumber+Panels)
Application
Wood Building Systems
Author
Ni, Chun
Popovski, Marjan
Wang, Jasmine
Karacabeyli, Erol
Year of Publication
2016
Country of Publication
Austria
Format
Conference Paper
Material
Light Frame (Lumber+Panels)
Application
Wood Building Systems
Topic
Design and Systems
Keywords
Mid-Rise
Dynamic Analysis
Deflection
Diaphragm
National Building Code of Canada
Capacity-Based Design
Language
English
Conference
World Conference on Timber Engineering
Research Status
Complete
Notes
August 22-25, 2016, Vienna, Austria p. 5343-5351
Summary
The following topics in the field of seismic analysis and design of mid-rise (5- and 6-storey) wood-frame buildings are included in this paper: Determination of the building period, linear dynamic analysis of wood-frame structures, deflections of stacked multi-storey shearwalls, diaphragm classification, capacity-based design for woodframe...
Online Access
Free
Resource Link
Less detail

Advanced Wood-Based Solutions for Mid-Rise and High-Rise Construction: Analytical Models for Balloon-Type CLT Shear Walls

https://research.thinkwood.com/en/permalink/catalogue1877
Year of Publication
2018
Topic
Design and Systems
Material
CLT (Cross-Laminated Timber)
Application
Walls
Author
Chen, Zhiyong
Cuerrier-Auclair, Samuel
Popovski, Marjan
Organization
FPInnovations
Year of Publication
2018
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Application
Walls
Topic
Design and Systems
Keywords
Lateral Loads
Shear
Mass Timber
Language
English
Research Status
Complete
Notes
Report is currently not available due to the redevelopment of FPInnovations' publications website.
Summary
Lack of research and design information for the seismic performance of balloon-type CLT shear walls prevents CLT from being used as an acceptable solution to resist seismic loads in balloon-type mass-timber buildings. To quantify the performance of balloon-type CLT structures subjected to lateral loads and create the research background for future code implementation of balloon-type CLT systems in CSA O86 and NBCC, FPInnovations initiated a project to determine the behaviour of balloon-type CLT construction. A series of tests on balloon-type CLT walls and connections used in these walls were conducted. Analytical models were developed based on engineering principles and basic mechanics to predict the deflection and resistance of the balloon-type CLT shear walls. This report covers the work related to development of the analytical models and the tests on balloon-type CLT walls that the models were verified against.
Online Access
Free
Resource Link
Less detail

Advanced Wood-Based Solutions for Mid-Rise and High-Rise Construction: Exit Fire Separations in Mid-Rise Wood Buildings

https://research.thinkwood.com/en/permalink/catalogue1879
Year of Publication
2018
Topic
Fire
Design and Systems
Application
Wood Building Systems
Author
Ranger, Lindsay
Dagenais, Christian
Organization
FPInnovations
Year of Publication
2018
Country of Publication
Canada
Format
Report
Application
Wood Building Systems
Topic
Fire
Design and Systems
Keywords
National Building Code of Canada
Combustible Material
Mid-Rise
Noncombustible Construction
Language
English
Research Status
Complete
Notes
Report is currently not available due to the redevelopment of FPInnovations' publications website.
Online Access
Free
Resource Link
Less detail

Air-Coupled Ultrasound Propagation and Novel Non-Destructive Bonding Quality Assessment of Timber Composites

https://research.thinkwood.com/en/permalink/catalogue13
Year of Publication
2012
Topic
Mechanical Properties
Material
Glulam (Glue-Laminated Timber)
Application
General Application

Airtightness and Air Leakage Causes of Wooden Houses in Korea

https://research.thinkwood.com/en/permalink/catalogue1643
Year of Publication
2016
Topic
Energy Performance
Material
CLT (Cross-Laminated Timber)
Light Frame (Lumber+Panels)
Application
Wood Building Systems
Author
Kim, Se-Jong
Chang, Yoon-Seong
Park, Joo-Saeng
Year of Publication
2016
Country of Publication
Austria
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Light Frame (Lumber+Panels)
Application
Wood Building Systems
Topic
Energy Performance
Keywords
Korea
Airtightness
Air Leakage
Language
English
Conference
World Conference on Timber Engineering
Research Status
Complete
Notes
August 22-25, 2016, Vienna, Austria p. 3367-3372
Summary
The airtightness of building must be measured for the evaluation of building energy performance. To make up the reference airtightness value of wooden houses built in Korea, blower door test was carried out in the 36 houses. And, during the test, the causes of air leakage were inspected simultaneously. The result showed that the...
Online Access
Free
Resource Link
Less detail

An Analytical Model for Design of Reinforcement around Holes in Laminated Veneer Lumber (LVL) Beams

https://research.thinkwood.com/en/permalink/catalogue135
Year of Publication
2013
Topic
Design and Systems
Mechanical Properties
Material
LVL (Laminated Veneer Lumber)
Application
Beams

10 records – page 1 of 1.