Skip header and navigation

10 records – page 1 of 1.

Assessing the Fire Integrity Performance of Cross-Laminated Timber Floor Panel-To-Panel Joints

https://research.thinkwood.com/en/permalink/catalogue185
Year of Publication
2016
Topic
Connections
Fire
Material
CLT (Cross-Laminated Timber)
Application
Floors
Author
Dagenais, Christian
Organization
Carleton University
Year of Publication
2016
Country of Publication
Canada
Format
Thesis
Material
CLT (Cross-Laminated Timber)
Application
Floors
Topic
Connections
Fire
Keywords
Finite Element Model
Thickness
Codes
Panel-to-Panel
Joints
Canada
US
Fire Resistance
Language
English
Research Status
Complete
Abstract
During the past few years, a relatively new technology has emerged in North America and changed the way professionals design and build wood structures: Cross-laminated Timber (CLT). CLT panels are manufactured in width ranging from 600 mm to 3 m. As such...
Online Access
Free
Resource Link
Less detail

Chapter 8: Fire Performance of Cross-Laminated Timber Assemblies

https://research.thinkwood.com/en/permalink/catalogue827
Year of Publication
2013
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Application
Walls
Floors
Author
Dagenais, Christian
White, Robert
Sumathipala, Kuma
Organization
FPInnovations
Binational Softwood Lumber Council
Year of Publication
2013
Country of Publication
Canada
United States
Format
Book Section
Material
CLT (Cross-Laminated Timber)
Application
Walls
Floors
Topic
Fire
Keywords
Charring Rate
Fire Resistance
Language
English
Research Status
Complete
Series
CLT Handbook - US Edition
ISBN
978-0-86488-553-1
ISSN
1925-0495
Abstract
Cross-laminated timber (CLT) is a promising wood-based structural component and has potential to provide cost-effective building solution for residential, commercial and institutional buildings as well as large industrial facilities. Market acceptance of CLT requires that it meets the applicable building code requirements. CLT elements are used in building systems in similar manner to concrete slabs and solid wall elements, as well as to those from heavy timber construction, by avoiding concealed spaces due to the use of massive timber elements, thus reducing the risk of fire spread beyond its point of origin. Moreover, CLT construction typically uses CLT panels for floor and loadbearing walls, will allow fire-rated compartmentalization, again reducing the risk of fire spread beyond it spoint of origin. ...
Online Access
Free
Resource Link
Less detail

Composite Concrete-CLT Floor Systems for Tall Building Design

https://research.thinkwood.com/en/permalink/catalogue2196
Material
CLT (Cross-Laminated Timber)
Application
Floors
Organization
TallWood Design Institute
Country of Publication
United States
Material
CLT (Cross-Laminated Timber)
Application
Floors
Keywords
Strength
Fire Resistance
Stiffness
Acoustics Virbration Characteristics
Research Status
In Progress
Notes
Contact: Christopher Higgins, Oregon State University, chris.higgins@oregonstate.edu
Abstract
This project will optimize the strength, stiffness, vibration characteristics, acoustic qualities and fire resistance of cross-laminated floor systems utilizing a composite concrete and cross-laminated timber product. This project includes development, testing and optimization of an economical shear connector (to connect the CLT panel to the concrete slab) that will be compared with existing screw and steel plate solutions. The resulting prototype floor system will be tested at full scale.
Less detail

Fireproof Tests and Heat Conduction Analyses for Development of 2-Hour Fire Resistant Structures

https://research.thinkwood.com/en/permalink/catalogue1778
Year of Publication
2016
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Application
Floors
Author
Kamikawa, Daisuke
Harada, Toshiro
Inada, Tatsuo
Kuratomi, Yoh
Shiozaki, Ikuo
Murata, Tadashi
Year of Publication
2016
Country of Publication
Austria
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Floors
Topic
Fire
Keywords
Furnace Fire Tests
Calcium Silicate Boards
Gypsum
Fire Resistance
Thickness
Heat Conduction Analysis
Numerical Model
Language
English
Conference
World Conference on Timber Engineering
Research Status
Complete
Notes
August 22-25, 2016, Vienna, Austria p. 5437-5444
Abstract
Small furnace fire tests were conducted on CLT cladded with calcium silicate boards, gypsum boards, and combinations of the two. The difference in fire resistance when using different board types, combinations, and thicknesses was demonstrated. Some cross-sectional configurations had enough 2-hour fire resistance performance...
Online Access
Free
Resource Link
Less detail

Fire-Resistance of Timber-Concrete Composite Floor Using Laminated Veneer Lumber

https://research.thinkwood.com/en/permalink/catalogue255
Year of Publication
2016
Topic
Connections
Fire
Material
LVL (Laminated Veneer Lumber)
Timber-Concrete Composite
Application
Floors
Author
Ranger, Lindsay
Dagenais, Christian
Cuerrier-Auclair, Samuel
Organization
FPInnovations
Year of Publication
2016
Country of Publication
Canada
Format
Report
Material
LVL (Laminated Veneer Lumber)
Timber-Concrete Composite
Application
Floors
Topic
Connections
Fire
Keywords
High-Rise
Structural Behaviour
Pull-Out Tests
shear connectors
Fire Resistance
Language
English
Research Status
Complete
Notes
Report is currently not available due to the redevelopment of FPInnovations' publications website.
Abstract
There is a need to demonstrate how novel timber-concrete composite floors can span long distances and be a practical alternative to other traditional structural systems. Better understanding of the fire behaviour of these hybrid systems is essential. To achieve this, the fire-resistance of a timber-concrete composite...
Online Access
Free
Resource Link
Less detail

Fire Resistance of Timber Framed Floor with Isolated Ceiling Assembly

https://research.thinkwood.com/en/permalink/catalogue685
Year of Publication
2014
Topic
Acoustics and Vibration
Fire
Material
Glulam (Glue-Laminated Timber)
Application
Floors
Ceiling
Author
Park, Joo-Saeng
Lee, Sang-Joon
Yeo, In-Hwan
Year of Publication
2014
Country of Publication
Canada
Format
Conference Paper
Material
Glulam (Glue-Laminated Timber)
Application
Floors
Ceiling
Topic
Acoustics and Vibration
Fire
Keywords
Heavy Impact Sound
Fire Resistance
Sound Insulation
Language
English
Conference
World Conference on Timber Engineering
Research Status
Complete
Notes
August 10-14, 2014, Quebec City, Canada
Abstract
Fire resistance test was performed for a floor assembly, of which stiffness was reinforced by shortening the span of floor joists by adding glulam beam in the middle of the original span, and which an additional ceiling component was installed apart from...
Online Access
Free
Resource Link
Less detail

Fire Resistance of Unprotected Cross-Laminated Timber Wall and Floor Assemblies Made in the USA

https://research.thinkwood.com/en/permalink/catalogue2063
Year of Publication
2018
Topic
Fire
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
Application
Walls
Floors

Fire Resistance Testing of CLT Floor/Ceiling Assemblies

https://research.thinkwood.com/en/permalink/catalogue1721
Year of Publication
2016
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Application
Ceilings
Floors
Organization
Oregon State University
Year of Publication
2016
Country of Publication
United States
Format
Report
Material
CLT (Cross-Laminated Timber)
Application
Ceilings
Floors
Topic
Fire
Keywords
Fire Resistance
Load Bearing
Language
English
Research Status
Complete
Online Access
Free
Resource Link
Less detail

Fire-Resistance Test Report of E1 Stress Grade Cross-Laminated Timber Assemblies

https://research.thinkwood.com/en/permalink/catalogue356
Year of Publication
2013
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Application
Walls
Floors
Author
Ranger, Lindsay
Dagenais, Christian
Organization
FPInnovations
Year of Publication
2013
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Application
Walls
Floors
Topic
Fire
Keywords
National Building Code of Canada
Fire Resistance
Type X Gypsum Board
Language
English
Research Status
Complete
Notes
Report is currently not available due to the redevelopment of FPInnovations' publications website.
Abstract
A series of 3 cross-laminated timber (CLT) fire-resistance tests were conducted in accordance with ULC S101 standard as required in the National Building Code of Canada. The first two tests were 3-ply wall assemblies which were 105 mm thick, one unprotected and the other protected with an intumescent coating, FLAMEBLOC® GS 200, on the exposed surface...
Online Access
Payment Required
Resource Link
Less detail

Fire Tests on Loaded Cross-Laminated Timber Wall and Floor Elements

https://research.thinkwood.com/en/permalink/catalogue254
Year of Publication
2014
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Application
Floors
Walls
Author
Klippel, Michael
Leyder, Claude
Frangi, Andrea
Fontana, Mario
Publisher
International Association For Fire Safety Science
Year of Publication
2014
Country of Publication
Netherlands
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Floors
Walls
Topic
Fire
Keywords
Charring Rate
Canada
Panels
Fire Resistance
Language
English
Conference
Fire Safety Science International Symposium
Research Status
Complete
Notes
February 9-14, 2014, Christchurch, New Zealand
Online Access
Free
Resource Link
Less detail