Skip header and navigation

10 records – page 1 of 1.

Addendum to RR-335: Sound Transmission Through Nail-Laminated Timber (NLT) Assemblies

https://research.thinkwood.com/en/permalink/catalogue1868
Year of Publication
2018
Topic
Acoustics and Vibration
Material
NLT (Nail-Laminated Timber)
Application
Floors
Walls

Advanced Wood-Based Solutions for Mid-Rise and High-Rise Construction: Exit Fire Separations in Mid-Rise Wood Buildings

https://research.thinkwood.com/en/permalink/catalogue1879
Year of Publication
2018
Topic
Fire
Material
CLT (Cross-Laminated Timber)
NLT (Nail-Laminated Timber)
Application
Shafts and Chases
Author
Ranger, Lindsay
Dagenais, Christian
Organization
FPInnovations
Year of Publication
2018
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
NLT (Nail-Laminated Timber)
Application
Shafts and Chases
Topic
Fire
Keywords
National Building Code of Canada
Combustible Material
Mid-Rise
Noncombustible Construction
Language
English
Research Status
Complete
Summary
FPInnovations initiated this project to demonstrate the ability of wood exit stairs in mid-rise buildings to perform adequately in a fire when NBCC requirements are followed, with the intent of changing perceptions of the fire safety of wood construction. The objective of this research is to investigate further the fire safety afforded by exit stair shafts of combustible construction, with the ultimate objective of better consistency between the provincial and national building codes with respect to fire requirements for exit stair shafts in mid-rise wood-frame construction.
Online Access
Free
Resource Link
Less detail

Advanced Wood-Based Solutions for Mid-Rise and High-Rise Construction: In-Situ Testing of The Arbora Building for Vibration and Acoustic Performances

https://research.thinkwood.com/en/permalink/catalogue1179
Year of Publication
2018
Topic
Acoustics and Vibration
Design and Systems
Material
CLT (Cross-Laminated Timber)
Glulam (Glue-Laminated Timber)
Application
Wood Building Systems
Author
Hu, Lin
Cuerrier-Auclair, Samuel
Organization
FPInnovations
Year of Publication
2018
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Glulam (Glue-Laminated Timber)
Application
Wood Building Systems
Topic
Acoustics and Vibration
Design and Systems
Keywords
Sound Insulation
Tall Wood
Vibration Performance
Mid-Rise
Language
English
Research Status
Complete
Summary
This report addresses serviceability issues of tall wood buildings focusing on vibration and sound insulation performance. The sound insulation and vibration performance may not affect building's safety, but affects occupants' comfort and proper operation of the buildings and the funciton of sensitive equipment, consequently the acceptance of midrise and tall wood buildings in market place. Lack of data, knowledge and experience of sound and vibration performance of tall wood buildings is one of the issues related to design and construction of tall wood buildings.
Online Access
Free
Resource Link
Less detail

Advanced Wood-Based Solutions for Mid-Rise and High-Rise Construction: In-Situ Testing of the Brock Commons 18-Storey Building for Vibration and Acoustic performances

https://research.thinkwood.com/en/permalink/catalogue1180
Year of Publication
2018
Topic
Acoustics and Vibration
Material
CLT (Cross-Laminated Timber)
Application
Hybrid Building Systems
Author
Hu, Lin
Cuerrier-Auclair, Samuel
Organization
FPInnovations
Year of Publication
2018
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Application
Hybrid Building Systems
Topic
Acoustics and Vibration
Keywords
Non-Destructive Testing
Vibration Performance
Natural Frequencies
Damping Ratios
Sound Insulation
Ambient Vibration Testing
Apparent Sound Transmission Class
Language
English
Research Status
Complete
Summary
This report addresses serviceability issues of tall wood buildings focusing on their vibration and sound insulation performance. The sound insulation and vibration performance may not affect the building’s safety, but affects the occupants’ comfort and the proper operation of the buildings and the function of sensitive equipment...
Online Access
Free
Resource Link
Less detail

Advanced Wood-Based Solutions for Mid-Rise and High-Rise Construction: In-Situ Testing of the Origine 13-Storey Building for Vibration and Acoustic Performances

https://research.thinkwood.com/en/permalink/catalogue1474
Year of Publication
2018
Topic
Acoustics and Vibration
Serviceability
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Floors
Walls
Author
Hu, Lin
Cuerrier-Auclair, Samuel
Organization
FPInnovations
Year of Publication
2018
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Floors
Walls
Topic
Acoustics and Vibration
Serviceability
Keywords
Origine
Natural Frequencies
Damping Ratios
Sound Insulation
Ambient Vibration Tests
Static Deflection
Apparent Sound Transmission Class
Apparent Impact Insulation Class
Language
English
Research Status
Complete
Summary
Serviceability performance studied covers three different performance attributes of a building. These attributes are 1) vibration of the whole building structure, 2) vibration of the floor system, typically in regards to motions in a localized area within the entire floor plate, and 3) sound insulation performance of the wall and floor assemblies. Serviceability performance of a building is important as it affects the comfort of its occupants and the functionality of sensitive equipment as well. Many physical factors influence these performances. Designers use various parameters to account for them in their designs and different criteria to manage these performances. Lack of data, knowledge and experience of sound and vibration performance of tall wood buildings is one of the issues related to design and construction of tall wood buildings. In order to bridge the gaps in the data, knowledge, and experience of sound and vibration performance of tall wood buildings, FPInnovations conducted a three-phase performance testing on the Origine 13-storey CLT building of 40.9 m tall in Quebec city. It was the tallest wood building in Eastern Canada in 2017.
Online Access
Free
Resource Link
Less detail

Advanced Wood-Based Solutions for Mid-Rise and High-Rise Construction: Mid-Rise Wood Exit Shaft Demonstration Fire Test Report

https://research.thinkwood.com/en/permalink/catalogue1176
Year of Publication
2018
Topic
Fire
Application
Shafts and Chases
Author
Ranger, Lindsay
Dagenais, Christian
Bénichou, Noureddine
Organization
FPInnovations
Year of Publication
2018
Country of Publication
Canada
Format
Report
Application
Shafts and Chases
Topic
Fire
Keywords
Mid-Rise
Residential
Multi-Family
Exit Shafts
Language
English
Research Status
Complete
Summary
FPInnovations conducted a research project to study the construction of mid-rise wood exit shafts in Ontario and Québec. The scope of the project included an investigation into the concerns that have been raised in regards to the use of wood exits in mid-rise buildings, an analysis of recent Canadian fire statistics in residential multi-family structures, and a fire demonstration of a mass timber wall and supported light-frame floor. This report describes the fire demonstration completed as part of this project; this report acts as a supplement to the full project report.
Online Access
Free
Resource Link
Less detail

Advanced Wood-Based Solutions for Mid-Rise and High-Rise Construction: Modelling of Timber Connections Under Force and Fire

https://research.thinkwood.com/en/permalink/catalogue1473
Year of Publication
2018
Topic
Connections
Fire
Seismic
Design and Systems
Material
LVL (Laminated Veneer Lumber)
Glulam (Glue-Laminated Timber)
Application
Beams
Author
Chen, Zhiyong
Ni, Chun
Dagenais, Christian
Organization
FPInnovations
Year of Publication
2018
Country of Publication
Canada
Format
Report
Material
LVL (Laminated Veneer Lumber)
Glulam (Glue-Laminated Timber)
Application
Beams
Topic
Connections
Fire
Seismic
Design and Systems
Keywords
Finite Element Model
Bolted Connection
Load-Displacement Curves
Language
English
Research Status
Complete
Summary
FPInnovations carried out a survey with consultants and researchers on the use of analytical models and software packages related to the analysis and design of mass timber buildings. The responses confirmed that a lack of suitable models and related information for material properties of timber connections was creating an impediment to the design and construction of this type of buildings. Furthermore, there is currently a lack of computer models and expertise for carrying out performance-based design for wood buildings, in particular seismic and/or fire performance design. In this study, a sophisticated constitutive model for wood-based composite material under stress and temperature was developed. This constitutive model was programmed into a user-subroutine which can be added to most general-purpose finite element software. The developed model was validated with test results of a laminated veneer lumber (LVL) beam and glulam bolted connection under force and/or fire.
Online Access
Free
Resource Link
Less detail

Analyse de Performance Acoustique et de Résistance au Feu

https://research.thinkwood.com/en/permalink/catalogue2752
Year of Publication
2018
Topic
Acoustics and Vibration
Fire
Material
CLT (Cross-Laminated Timber)
Glulam (Glue-Laminated Timber)
Organization
Société en commandite NEB
Year of Publication
2018
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Glulam (Glue-Laminated Timber)
Topic
Acoustics and Vibration
Fire
Keywords
Origine
Fire Resistance
Acoustic Performance
Tall Timber
Multi-Storey
Language
French
Research Status
Complete
Summary
Le présent rapport décrit une partie des activités de recherche et développement (R&D) en lien avec la démonstration de la résistance au feu ainsi que les études sur la performance acoustique effectuées dans le cadre de la construction du bâtiment Origine. Ce bâtiment est la tour résidentielle en bois massif la plus haute au Québec. Sa réalisation a débuté en 2015 à la suite des analyses préliminaires de faisabilité technique-économique qui se sont étalées pendant toute l’année 2014. La construction et l’installation se sont finalisées vers la fin de 2017. En premier lieu, le rapport présente les démarches liées à la réalisation d’un exercice de démonstration d’incendie pour une cage d’escaliers/ascenseur avec une chambre d’habitation adjacente, l’analyse de résultats et les principales conclusions en lien avec la pertinence de l’utilisation du bois massif pour des édifices de grande hauteur. En ce qui concerne la performance acoustique, le rapport présente la méthodologie d’étude et d’analyse des résultats des tests acoustiques pour des assemblages de mur et de plancher utilisés dans le projet Origine. De plus, ce rapport facilite la compréhension des activités réalisées et permet de montrer objectivement la capacité des produits en bois massif à offrir un environnement sécuritaire et confortable aux occupants de bâtiments multi-étagés. Les principaux résultats indiquent que les cages d’escaliers/ascenseur faites en bois massif, conçues pour une résistance au feu équivalente à celle faites en béton, peuvent offrir une excellente performance et servent d’alternatives adéquates pour les bâtiments multi-étagés. En ce qui concerne le développement d’assemblages acoustiques pour les murs et les planchers en bois massif, il a été prouvé qu’une approche multicritère permet d’offrir des solutions performantes à des coûts raisonnables. Finalement, il est clair que ce projet constitue un jalon très important dans le chemin d’acceptation des bâtiments multi-étagés en bois massif au Québec et au Canada. Sa construction, faite presque entièrement en bois, a nécessité de nombreux efforts économiques, de R&D, de conception et d’installation. De plus, les activités réalisées pour l’acceptation de ce type de construction ont permis de mettre en place de nouvelles technologies et des techniques de conception qui faciliteront la réplication de ce type de projet partout en Amérique du Nord.
Online Access
Free
Resource Link
Less detail

Blast Testing of Loaded Mass Timber Structures

https://research.thinkwood.com/en/permalink/catalogue1164
Year of Publication
2018
Topic
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
NLT (Nail-Laminated Timber)
Application
Walls

Brock Commons Tallwood House, University of British Columbia: An Environmental Building Declaration According to EN 15978 Standard

https://research.thinkwood.com/en/permalink/catalogue2158
Year of Publication
2018
Topic
Environmental Impact
Material
CLT (Cross-Laminated Timber)
Glulam (Glue-Laminated Timber)
Application
Hybrid Building Systems

10 records – page 1 of 1.