Skip header and navigation

10 records – page 1 of 1.

Assess Fire Spread in Floor Voids

https://research.thinkwood.com/en/permalink/catalogue796
Year of Publication
2013
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Light Frame (Lumber+Panels)
Application
Floors
Author
Ranger, Lindsay
Organization
FPInnovations
Year of Publication
2013
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Light Frame (Lumber+Panels)
Application
Floors
Topic
Fire
Keywords
National Building Code of Canada
Flame Spread
Language
English
Research Status
Complete
Summary
Some innovative and structurally efficient uses of massive wood panels, such as cross-laminated timber (CLT), will result in hollow structural sections. Light-weight wood construction as well as heavy timber assemblies using dropped ceilings or raised fl...
Online Access
Free
Resource Link
Less detail

Bending Tests on Glued Laminated Timber Beams with Well-Known Material Properties

https://research.thinkwood.com/en/permalink/catalogue186
Year of Publication
2013
Topic
Mechanical Properties
Material
Glulam (Glue-Laminated Timber)
Application
Beams

A Comparative Life Cycle Assessment of Two Multistory Residential Buildings: Cross-Laminated Timber Vs. Concrete Slab and Column with Light Gauge Steel Walls

https://research.thinkwood.com/en/permalink/catalogue339
Year of Publication
2013
Topic
Environmental Impact
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Author
Grann, Blane
Organization
FPInnovations
Year of Publication
2013
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Topic
Environmental Impact
Keywords
Concrete
Life-Cycle Assessment
Mid-Rise
Steel
Canada
Language
English
Research Status
Complete
Summary
This study provides a comparative life cycle assessment (LCA) of a 4060 m2, 4-storey cross laminated timber (CLT) apartment building located in Quebec City, Canada and an equivalently designed building consisting of reinforced concrete slabs and columns with light gauge steel studded walls (CSSW)...
Online Access
Free
Resource Link
Less detail

Cross-Laminated Timber Roof Panels at the Promega Corporation Facility: Documenting Installation and Monitoring In-Service Moisture Conditions

https://research.thinkwood.com/en/permalink/catalogue801
Year of Publication
2013
Topic
Serviceability
Moisture
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Author
Glass, Samuel
Romanin, Jennifer
Schumacher, Jim
Spickler, Kris
Organization
Forest Products Laboratory
Year of Publication
2013
Country of Publication
United States
Format
Report
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Topic
Serviceability
Moisture
Keywords
Moisture
Temperature
Installation Process
Sensors
Language
English
Research Status
Complete
Summary
The USDA Forest Products Laboratory (FPL) has, for the past two years, been assisting in removing technical barriers to the use of CLT and trying to develop interest in the United States for its utilization. Coincidentally, Promega Corporation, a leader ...
Online Access
Free
Resource Link
Less detail

Fire Performance Requirements of Non-Load-Bearing Wood-Frame In-Fill Walls in Concrete/Steel Hybrid Buildings. Part 1 - Literature Review of International Building Code

https://research.thinkwood.com/en/permalink/catalogue2621
Year of Publication
2013
Topic
Fire
Material
Light Frame (Lumber+Panels)
Application
Walls
Hybrid Building Systems
Author
Lu, Ling
Organization
FPInnovations
Year of Publication
2013
Format
Report
Material
Light Frame (Lumber+Panels)
Application
Walls
Hybrid Building Systems
Topic
Fire
Keywords
Fire-Retardant-Treatment (FRT)
Fire Resistance Rating
Building Code
Construction
Exterior Wall
Non-Loadbearing
Concrete
Steel
Mid-Rise
Language
English
Research Status
Complete
Summary
Related sections in the International Building Code (IBC) were reviewed regarding use of wood components in non-combustible buildings, and light-frame wood buildings or heavy timber buildings greater than 4-storeys in height. The highlights of this review are: a) Fire-retardant-treated (FRT) wood can be used in partitions when the required fire-resistance rating is not more than 2 hours. This includes all types and occupancy groups of Types I and II construction; b) FRT wood can be used in non-bearing exterior walls in Type I, II, III and IV construction; c) Wood components can be used in interior walls for Type III and IV construction; d) Wood components can be used in both interior and exterior walls for Type V construction. When a sprinkler system is installed according to NFPA 13 [1], it is possible to build a light-frame wood building or heavy timber building over 4-storeys according to the following provisions: a) Type IIIA 6-storey light-frame wood buildings using FRT wood for exterior walls for Occupancy group B (Business), H-4, and 5-storey light-frame wood buildings for Occupancy group F-2, H-3, I-1(Institutional), R (Residential), S-2; b) Type IIIB 5-storey light-frame wood buildings using FRT wood for exterior walls for Occupancy group R; c) Type IV (HT) 6-storeys timber buildings for Occupancy group B, F-2, H-4 and S-2; d) Type IV (HT) 5-storeys timber buildings for Occupancy group F-1, H-3, I-1, R, S-1 and U.
Online Access
Free
Resource Link
Less detail

Fire Performance Requirements of Non-Load-Bearing Wood-Frame In-Fill Walls in Concrete/Steel Hybrid Buildings. Part 2 - Review of the National Building Code of Canada

https://research.thinkwood.com/en/permalink/catalogue2622
Year of Publication
2013
Topic
Fire
Material
Light Frame (Lumber+Panels)
Application
Walls
Hybrid Building Systems
Author
Lu, Ling
Organization
FPInnovations
Year of Publication
2013
Country of Publication
Canada
Format
Report
Material
Light Frame (Lumber+Panels)
Application
Walls
Hybrid Building Systems
Topic
Fire
Keywords
Non-Loadbearing
Fire Resistance
Concrete
Steel
Building Code
Fire Performance
Exterior Wall
Sprinklers
Mid-Rise
Language
English
Research Status
Complete
Summary
This project evaluates the National Building Codes of Canada (NBCC) clauses relevant to fire performance and performance requirements of non-load-bearing wood-frame in-fill walls in concrete/steel hybrid buildings. Related clauses in NBCC are reviewed regarding the use of wood components and non-load bearing wall systems in non-combustible buildings. The highlights of this review are: § An exterior non-loadbearing wall assembly with combustible components is allowed in non-combustible construction if: a) Building height is not more than 3 storeys or has a sprinkler system throughout ; b) The interior surfaces of the wall assembly are protected by a thermal barrier ; and c) The wall assembly satisfied the testing criteria for CAN/ULC S134 ; § Combustible interior wall finishes, other than foamed plastics, are allowed in non-combustible construction if the thickness is not greater than 25 mm and their flame spread rating (FSR) is not more than 150 ; § Combustible insulation, other than foamed plastics, is allowed in non-combustible construction if the flame-spread rating not more than 25 ; § Combustible insulation with a FSR not less than 25 and not more than 500 is allowed in exterior and interior walls of non-combustible construction if the building is non-sprinklered and not more than 18 m or sprinklered and protected by a thermal barrier ; § There are no obstacles for using wood-frame in-fill wall systems for interior partition walls in hybrid buildings: a) For non-sprinklered buildings not greater than 3 storeys or a floor area not greater than 600 m2 ; b) For sprinklered buildings. § Non-combustible construction allows combustible elements in partition walls in the following instances: a) Solid lumber partitions located in a fire compartment area are permitted in a non-sprinklered floor area not greater than 600 m2 with restrictions ; b) Solid lumber partitions not less than 38 mm thick and partitions that contain wood framing are permitted with restrictions. § Combustible cladding can be used under the following circumstances: a) When a wall assembly with exposing building face is between 10 to 25% tested by CAN/ULC-S134 and complies with Article 3.1.5.5 ; b) When a wall assembly with exposing building face is between 25 to 50%, is sprinklered throughout, installed on a gypsum board sheathing, and has a FSR not more than 25 (with restrictions) ; c) When a wall assembly with exposing building face is between 50 to 100%, cladding can be combustible for group A, B, C, D, E, F. § When a building is required to be of non-combustible construction, combustible elements are limited to the requirements in Subsection 3.1.5 on non-combustible construction ; § When comparing the NBCC with the International Building Code (IBC), the IBC is more in favour of using FRT wood frame in-fill walls with one more storey.
Online Access
Free
Resource Link
Less detail

Fire-Resistance Test Report of E1 Stress Grade Cross-Laminated Timber Assemblies

https://research.thinkwood.com/en/permalink/catalogue356
Year of Publication
2013
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Application
Walls
Floors
Author
Ranger, Lindsay
Dagenais, Christian
Organization
FPInnovations
Year of Publication
2013
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Application
Walls
Floors
Topic
Fire
Keywords
National Building Code of Canada
Fire Resistance
Type X Gypsum Board
Language
English
Research Status
Complete
Summary
A series of 3 cross-laminated timber (CLT) fire-resistance tests were conducted in accordance with ULC S101 standard as required in the National Building Code of Canada. The first two tests were 3-ply wall assemblies which were 105 mm thick, one unprotected and the other protected with an intumescent coating, FLAMEBLOC® GS 200, on the exposed surface...
Online Access
Free
Resource Link
Less detail

Fire Safe Glued Massive Timber Members Adhesive Bonding Performance under Elevated Temperature -Tests Report

https://research.thinkwood.com/en/permalink/catalogue169
Year of Publication
2013
Topic
Fire
Mechanical Properties
Material
Solid-sawn Heavy Timber
Author
Zhang, Chao
Yan, Huijun
Lee, George
Lam, Frank
Organization
Forestry Innovation Investment
Year of Publication
2013
Country of Publication
Canada
Format
Report
Material
Solid-sawn Heavy Timber
Topic
Fire
Mechanical Properties
Keywords
Temperature
Adhesives
Bondlines
Polyurethane
Douglas-Fir
Hemlock
SPF
Phenol-Resorcinol Formaldehyde
Epoxy
Language
English
Research Status
Complete
Summary
This project was conducted to quantify the performance of adhesives bond lines under shear load subject to elevated temperature. The results add to the understanding of the performance of polyurethane adhesive bond lines under elevated temperatures to ad...
Online Access
Free
Resource Link
Less detail

Fire Safety Challenges of Tall Wood Buildings

https://research.thinkwood.com/en/permalink/catalogue1095
Year of Publication
2013
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Glulam (Glue-Laminated Timber)
Application
Wood Building Systems

Life Cycle Assessment of a Cross Laminated Timber Building

https://research.thinkwood.com/en/permalink/catalogue66
Year of Publication
2013
Topic
Environmental Impact
Energy Performance
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems

10 records – page 1 of 1.