Skip header and navigation

Refine Results By

10 records – page 1 of 1.

Effects of Exposed Cross Laminated Timber on Compartment Fire Dynamics

https://research.thinkwood.com/en/permalink/catalogue1340
Year of Publication
2017
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Application
Rooms

Description of Small and Large-Scale Cross Laminated Timber Fire Tests

https://research.thinkwood.com/en/permalink/catalogue1339
Year of Publication
2017
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Application
Rooms
Wood Building Systems

Fundamentals for the Fire Design of Cross Laminated Timber Buildings

https://research.thinkwood.com/en/permalink/catalogue2310
Year of Publication
2017
Topic
Fire
Design and Systems
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems

Fire Resistance of Large-Scale Cross-Laminated Timber Panels

https://research.thinkwood.com/en/permalink/catalogue2219
Year of Publication
2017
Topic
Fire
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
Application
Walls
Wood Building Systems
Author
Henek, Vladan
Venkrbec, Václav
Novotný, Miloslav
Publisher
IOP Publishing Ltd
Year of Publication
2017
Country of Publication
Czech Republic
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Walls
Wood Building Systems
Topic
Fire
Mechanical Properties
Keywords
Fire Resistance
European Standards
Language
English
Conference
World Multidisciplinary Earth Sciences Symposium
Research Status
Complete
Online Access
Free
Resource Link
Less detail

Structural Response of Cross-Laminated Timber Compression Elements Exposed to Fire

https://research.thinkwood.com/en/permalink/catalogue1338
Year of Publication
2017
Topic
Fire
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
Application
Walls

Investigating Heat Release Rate and Fire Growth Contribution of Cross-Laminated Timber — A Preliminary Study

https://research.thinkwood.com/en/permalink/catalogue2605
Year of Publication
2017
Topic
Fire
Design and Systems
Material
CLT (Cross-Laminated Timber)
Author
Dagenais, Christian
Organization
FPInnovations
Year of Publication
2017
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Topic
Fire
Design and Systems
Keywords
Heat Release Rate
Fire Growth Contribution
Heat Delamination Characteristics
Adhesives
Language
English
Research Status
Complete
Summary
The main objective of this preliminary study is to evaluate the heat release rate and fire growth contribution due to heat delamination characteristics of CLT manufactured with current certified ANSI/APA PRG-320 adhesives used for face bonding, when exposed to a constant radiant heat flux. The evaluation is performed using the principles of ISO 5660-1 “Reaction-to-fire tests - Heat release, smoke production and mass loss rate – Part 1: Heat release rate (cone calorimeter method)” [19]. The American version of this test method is ASTM E1354 « Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter » [20]. The long-term objective is to determine which currently accepted test methods allow for a better evaluation of heat delamination characteristics of adhesives used in structural engineered wood products, based on their actual end-use applications (e.g. bending, compression, combined stress, cross-plies, etc.)
Online Access
Free
Resource Link
Less detail

Shear Behavior of Cross-Laminated Timber Wall Consisting of Small Panels

https://research.thinkwood.com/en/permalink/catalogue1411
Year of Publication
2017
Topic
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Author
Oh, Jung-Kwon
Hong, Jung-Pyo
Kim, Chul-Ki
Pang, Sung-Jun
Lee, Sang-Joon
Lee, Jun-Jae
Publisher
Springer Japan
Year of Publication
2017
Country of Publication
Japan
Format
Journal Article
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Topic
Mechanical Properties
Keywords
Kinematic Model
Peak Load
Displacement
Panel-to-Panel
Language
English
Research Status
Complete
Series
Journal of Wood Science
Online Access
Free
Resource Link
Less detail

Behavior of Cross-Laminated Timber Diaphragm Panel-to-Panel Connections with Self-Tapping Screws

https://research.thinkwood.com/en/permalink/catalogue1422
Year of Publication
2017
Topic
Seismic
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems

Fire Performance of ASTM E119 Evaluation of CLT Load-Bearing Wall Assemblies

https://research.thinkwood.com/en/permalink/catalogue1720
Year of Publication
2017
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Application
Walls
Organization
Oregon State University
Year of Publication
2017
Country of Publication
United States
Format
Report
Material
CLT (Cross-Laminated Timber)
Application
Walls
Topic
Fire
Keywords
Fire Resistance
Load Bearing
Temperature
Language
English
Research Status
Complete
Online Access
Free
Resource Link
Less detail

Commentary on Closure Penetration Tests on CLT Fire Separations

https://research.thinkwood.com/en/permalink/catalogue2602
Year of Publication
2017
Topic
Fire
Design and Systems
Material
CLT (Cross-Laminated Timber)
Application
Walls
Author
Lum, Conroy
Thomas, Tony
Organization
FPInnovations
Year of Publication
2017
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Application
Walls
Topic
Fire
Design and Systems
Keywords
Fire Resistance
Fire Tests
Panels
Language
English
Research Status
Complete
Summary
Fire tests on a double egress fire door installed in two Cross Laminated Timber (CLT) wall panels were conducted. The purpose of the testing was to identify design consideration for detailing the interface between a 90 min. listed door assembly and a CLT wall with a 2-hr fire resistance. See also QAI Laboratories test reports: T895-6a Rev.2, and T895-6b Rev. 1
Online Access
Free
Resource Link
Less detail

10 records – page 1 of 1.