Skip header and navigation

Refine Results By

10 records – page 1 of 1.

Executive Report: Full-Scale Shake Table Testing of a Two-Story Mass Timber Building with Resilient Rocking Wall Lateral System

https://research.thinkwood.com/en/permalink/catalogue1151
Year of Publication
2017
Topic
Seismic
Design and Systems
Material
CLT (Cross-Laminated Timber)
Timber-Concrete Composite
Application
Wood Building Systems

Nail Laminated Timber Compartment Fire Tests

https://research.thinkwood.com/en/permalink/catalogue2165
Year of Publication
2019
Topic
Fire
Design and Systems
Material
NLT (Nail-Laminated Timber)
Glulam (Glue-Laminated Timber)
Application
Rooms
Wood Building Systems

Fire Safety Challenges of Tall Wood Buildings – Phase 2: Task 2 & 3 – Cross Laminated Timber Compartment Fire Tests

https://research.thinkwood.com/en/permalink/catalogue1214
Year of Publication
2018
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems

Fire Testing for Framework Office Building in Portland, OR

https://research.thinkwood.com/en/permalink/catalogue1828
Year of Publication
2017
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Glulam (Glue-Laminated Timber)
Application
Wood Building Systems
Beams
Columns
Organization
SWRI
Year of Publication
2017
Country of Publication
United States
Format
Report
Material
CLT (Cross-Laminated Timber)
Glulam (Glue-Laminated Timber)
Application
Wood Building Systems
Beams
Columns
Topic
Fire
Keywords
Fire Endurance Tests
Connections
Assembly
Fabrication
Thermocouples
Beam Column Connection
Language
English
Research Status
Complete
Series
Framework: An Urban + Rural Design
Summary
A. Fire Test Results Summary B. Test 1a (Test 1): Beam-Exterior Column Connection Report C. Test 1a (Test 2): Beam-Exterior Column Connection Report D. Test 1a (Test 3): Beam-Exterior Column Connection Report E. Test 1a (Test 4): Beam-Exterior Column Connection Report F. Test 1b (Test 1): CLT Deck to Beam Report G. Test 1b (Test 2): CLT Deck to Beam Report H. Test 1b (Test 3): CLT Deck to Beam Report I. Test 1c: Penetrations Fire Resistance Rating Report (TBD) J. Test 1d: Wall Fire Resistance Rating Report
Online Access
Free
Resource Link
Less detail

Fire Testing of Rooms with Exposed Wood Surfaces in Encapsulated Mass Timber Construction

https://research.thinkwood.com/en/permalink/catalogue1867
Year of Publication
2018
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Author
Su, Joseph
Leroux, Patrice
Lafrance, Pier-Simon
Berzins, Robert
Gibbs, Eric
Weinfurter, Mark
Organization
National Research Council of Canada
Publisher
National Research Council Canada. Construction
Year of Publication
2018
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Topic
Fire
Keywords
Encapsulated
Mass Timber
Fire Tests
Fire Performance
Char Layer
Fire Regrowth
Language
English
Research Status
Complete
Series
Client Report (National Research Council Canada. Construction)
Online Access
Free
Resource Link
Less detail

Report of Testing Cross-Laminated Timber Panels for Compliance With CAN/ULC-S101 Standard Methods of Fire Endurance Test of Building Construction and Materials: Loadbearing 3-Ply CLT Wall with 1 Layer Of 5/8'' Fire-Rated Gypsum Board (60% Load)

https://research.thinkwood.com/en/permalink/catalogue745
Year of Publication
2013
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Application
Walls
Organization
Canadian Wood Council
Year of Publication
2013
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Application
Walls
Topic
Fire
Keywords
Fire Resistance
Load Bearing Walls
Type X Gypsum Board
Panels
Language
English
Research Status
Complete
Summary
Intertek Testing Services NA, Inc. (Intertek) has conducted testing for the Canadian Wood Council, on Cross-Laminated Timber Panels, to evaluate their fire resistance. Testing was conducted in accordance with the applicable requirements, and following th...
Online Access
Free
Resource Link
Less detail

Report of Testing Cross Laminated Timber Panels for Compliance with CAN/ULC-S101 Standard Methods of Fire Endurance Tests of Building Construction and Materials: Loadbearing 3-Ply CLT Wall with Attached Wood Frame Partition

https://research.thinkwood.com/en/permalink/catalogue746
Year of Publication
2012
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Application
Walls
Organization
Canadian Wood Council
Year of Publication
2012
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Application
Walls
Topic
Fire
Keywords
Fire Resistance
Load Bearing Walls
Mineral Wool Insulation
Type X Gypsum Board
Panels
Language
English
Research Status
Complete
Summary
Intertek Testing Services NA, Inc. (Intertek) has conducted testing for the Canadian Wood Council, on Cross-Laminated Timber Panels to evaluate their fire resistance. Testing was conducted in accordance with the applicable requirements, and following the...
Online Access
Free
Resource Link
Less detail

Review and Discussion of North American Building Codes and Fire Performance Design Criteria for Mass Timber with Focus on CLT

https://research.thinkwood.com/en/permalink/catalogue1878
Year of Publication
2018
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems

Report of Testing Cross Laminated Timber Panels for Compliance with Can/ULC-S101 Standard Methods of Fire Endurance Tests of Building Construction and Materials: Loadbearing 3-Ply CLT Wall with 1 Layer of 5/8'' Type X Gypsum Board

https://research.thinkwood.com/en/permalink/catalogue744
Year of Publication
2014
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Application
Walls
Organization
Canadian Wood Council
Year of Publication
2014
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Application
Walls
Topic
Fire
Keywords
Type X Gypsum Board
Panels
Fire Resistance
Load Bearing Walls
Language
English
Research Status
Complete
Summary
Intertek Testing Services NA, Inc. (Intertek) has conducted testing for the Canadian Wood Council, on Cross-Laminated Timber Panels, to evaluate their fire resistance. Testing was conducted in accordance with the applicable requirements, and following th...
Online Access
Free
Resource Link
Less detail

Preliminary CLT Fire Resistance Testing Report

https://research.thinkwood.com/en/permalink/catalogue377
Year of Publication
2012
Topic
Fire
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Organization
FPInnovations
Year of Publication
2012
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems
Topic
Fire
Keywords
Full Scale
Fire Resistance
Type X Gypsum Board
Thermocouples
Language
English
Research Status
Complete
Summary
FPInnovations is involved in a large research project regarding CLT construction. One objective of this research is the creation of a design methodology for calculating the fire-resistance of CLT assemblies/construction. This methodology will foster the design of fire-safe buildings of wood or hybrid construction. In order to establish such calculation methods, a series of experimental tests has been undertaken. A total of eight full-scale CLT fire resistance tests have been conducted at the NRC fire laboratory where the panels were subject to the standard ULC S101 [1] fire exposure. The series consisted of three wall and five floor tests. Each test was unique using panels with a different number of plies and varying thicknesses. Some of the assemblies were protected using CGC Sheetrock® FireCode® Core Type X gypsum board while others were left unprotected.
Online Access
Free
Resource Link
Less detail

10 records – page 1 of 1.