Skip header and navigation

2 records – page 1 of 1.

Characteristics of the Radio-Frequency/Vacuum Drying of Heavy Timbers for Post and Beam of Korean Style Housings Part II: For Korean Red Pine Heavy Timbers with 250 × 250 mm, 300 × 300 mm in Cross Section and 300 mm in Diameter, and 3,600 mm in Length

https://research.thinkwood.com/en/permalink/catalogue1508
Year of Publication
2011
Topic
Moisture
Material
Solid-sawn Heavy Timber
Application
Wood Building Systems
Author
Lee, Nam-Ho
Zhao, Xue-Feng
Shin, Ik-Hyun
Park, Moon-Jae
Park, Jung-Hwan
Park, Joo-Saeng
Publisher
The Korean Society of Wood Science Technology
Year of Publication
2011
Country of Publication
Korea
Format
Journal Article
Material
Solid-sawn Heavy Timber
Application
Wood Building Systems
Topic
Moisture
Keywords
Radio-Frequency/Vacuum Drying
Moisture Gradient
Shrinkage
Case Hardening
Surface Checks
Compressive Load
Language
Korean
Research Status
Complete
Series
Journal of the Korean Wood Science and Technology
Online Access
Free
Resource Link
Less detail

Checking in CLT Panels: An Exploratory Study

https://research.thinkwood.com/en/permalink/catalogue2625
Year of Publication
2011
Topic
Moisture
Material
CLT (Cross-Laminated Timber)
Author
Casilla, Romulo
Lum, Conroy
Pirvu, Ciprian
Wang, Brad
Organization
FPInnovations
Year of Publication
2011
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Topic
Moisture
Keywords
Panels
Testing Methods
Surface Checks
Moisture Content
Gaps
Language
English
Research Status
Complete
Summary
A study was conducted with the primary objective of gathering information for the development of a protocol for evaluating the surface quality of cross-laminated timber (CLT) products. The secondary objectives were to examine the effect of moisture content (MC) reduction on the development of surface checks and gaps, and find ways of minimizing the checking problems in CLT panels. The wood materials used for the CLT samples were rough-sawn Select grade Hem-Fir boards 25 x 152 mm (1 x 6 inches). Polyurethane was the adhesive used. The development of checks and gaps were evaluated after drying at two temperature levels at ambient relative humidity (RH). The checks and gaps, as a result of drying to 6% to 10% MC from an initial MC of 13%, occurred randomly depending upon the characteristics of the wood and the manner in which the outer laminas were laid up in the panel. Suggestions are made for minimizing checking and gap problems in CLT panels. The checks and gaps close when the panels are exposed to higher humidity. Guidelines were proposed for the development of a protocol for classifying CLT panels into appearance grades in terms of the severity of checks and gaps. The grades can be based on the estimated dimensions of the checks and gaps, their frequency, and the number of laminas in which they appear.
Online Access
Free
Resource Link
Less detail