This paper describes selected observations, measurements, and analysis from a series of large-scale experiments on cross-laminated timber (CLT) slabs that were exposed to fire from below, using four different heating scenarios, with a sustained mechanical loading of 6.3 kN m per metre width of slab. The deflection response and in-depth timber temperatures are used to compare the experimental response against a relatively simple structural fire model to assess the load bearing capacity of CLT elements in fire, including during the decay phase of natural fires. It is demonstrated that the ventilation conditions in experiments with a fixed fuel load are important in achieving burnout of the contents before structural collapse occurs. A mechanics-based structural fire model is shown to provide reasonably accurate predictions of structural failure (or lack thereof) for the experiments presented herein. The results confirm the importance of the ventilation conditions on the fire dynamics, burning duration, and the achievement of functional fire safety objectives (i.e. maintaining stability and compartmentation), in compartments with exposed CLT.
This paper presents the results of long-term experiments performed on three timber-concrete composite (TCC) beams. An innovative fabricated steel plate connection system, which consists of screws and steel plates embedded in concrete slabs, was adopted in the TCC beam specimens. The adopted shear connection can provide dry-type connection for TCC beams. Steel plates were embedded in concrete slabs while the concrete slab was constructed in factories. The timber beam and concrete slab can be assembled together using screws at the construction site. In this experimental programme, the beam specimens were subjected to constant loading for 613 days in indoor uncontrolled environments. The influence of long-term loading levels and the number of shear connections on the long-term performance of TCC beams was investigated and discussed. The mid-span deflection, timber strain, and interface relative slip at the positions of both connections and beam-ends were recorded throughout the long-term tests. It was found the long-term deflection of the TCC beam increased by approximately 60% while the long-term loads were doubled. Under the influence of the variable temperature and humidity, the TCC specimens with 8 shear connections showed slighter fluctuations compared with the TCC beam with 6 shear connections. In the 613-day observation period, the maximum deflection increment recorded was 6.56 mm for the specimen with eight shear connections and 20% loading level. A rheological model consisting of two Kelvin bodies was employed to fit the curves of creep coefficients. The final deflections predicted of all specimens at the end of 50-year service life were 2.1~2.7 times the initial deflections caused by the applied loads. All beam specimens showed relative small increments in mid-span deflection, strain and relative slip over time without any degradations, demonstrating the excellent long-term performance of TCC beams using the innovative steel plate connection system, which is also easily fabricated.
Solutions for Upper Mid-Rise and High-Rise Mass Timber Construction: Fire Performance of Cross-Laminated Timber with Adhesives Conforming to 2018 edition of ANSI/APA PRG-320
The objective of this research is to evaluate CLT face-bonded with adhesives that meet the new 2018 ANSI/APA PRG 320 with respect to elevated temperature requirements and their effects on the resulting charring rates when exposed to the standard time-temperature curve of CAN/ULC S101 (similar exposure to ASTM E119)...
The increasing use of cross laminated timber (CLT) panels in large multi-story buildings has highlighted the structural performance of CLT in fire as a critical issue concerning life safety and serviceability. It is well-known that wood material strength decreases when exposed to elevated temperature for an extended period of time. For CLT panels, another level of complexity lies in the mechanical properties of the glued interface under high temperature. In this study, the tensile strength of typical North American wood species and shear strength of the glued interface of commonly used adhesives in CLT production were evaluated at different levels of elevated temperatures. The researchers systematically tested glue interface and wood samples in a controlled temperature chamber and obtained the load-deformation curves of the specimens until failure was observed. A total of five temperature levels were tested, with three wood species and four wood adhesive types. The glued interface strength was also compared to wood material strength itself under different temperatures. For each test, multiple samples were tested to ensure statistical significance of the results. The ultimate objective of this study is to develop a mechanistic model for CLT panels that can take into account the effect of temperature. In this paper, only the design, execution, and results from the elevated temperature tests are presented.
This article presents a test method that was developed to screen adhesive formulations for finger-jointed lumber. The goal was to develop a small-scale test that could be used to predict whether an adhesive would pass a full-scale ASTM E119 wall assembly test. The method involved loading a 38-mm square finger-jointed sample in a four-point bending test inside of an oven with a target sample temperature of 204°C. The deformation (creep) was examined as a function of time. It was found that samples fingerjointed with melamine formaldehyde and phenol resorcinol formaldehyde adhesives had the same creep behavior as solid wood. One-component polyurethane and polyvinyl acetate adhesives could not maintain the load at the target temperature measured middepth of the sample, and several different types of creep behavior were observed before failure. This method showed that the creep performance of the onecomponent adhesives may be quite different than the performance from short-term load deformation curves collected at high temperatures. The importance of creep performance of adhesives in the fire resistance of engineered wood is discussed.
The performance of timber in fire is often assessed by measuring the temperature at different positions in the specimen. As timber is a low conductive material, it can be difficult to measure the correct temperature.Therefore, this paper shows how to correctly measure the temperature in timber members and how to describe temperature measurements of fire tests and experiments non-ambiguously.Typical temperature measurement setups used in tests and experiments were experimentally assessed under ISO/EN fire exposure and a constant incident radiant heat flux. By comparing the charring depth and the thermocouple readings(charring temperature 300°C) it was found that only the wire thermocouples inlaid parallel to the isotherms deliver correct temperature readings. For other temperature measurement setups, the underestimation was between 5 and 20 minutes.Due to the numerous factors influencing the measurement error, no correction factor could be defined.