Effect of Opening on Seismic Performance of CLT Panel: Part. 2 Bending Shear Test of L-Shape Specimen Panel

https://research.thinkwood.com/en/permalink/catalogue942
Year of Publication
2015
Topic
Seismic
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems

Study on Shear Performance of CLT Joints Using Long Vise Part 1 Summary of Experiments and Test Pieces

https://research.thinkwood.com/en/permalink/catalogue1009
Year of Publication
2014
Topic
Connections
Material
CLT (Cross-Laminated Timber)
Application
Floors
Walls

Lateral Loading Tests on CLT Shear Walls by Assembly of Narrow Panels and by a Large Panel with an Opening

https://research.thinkwood.com/en/permalink/catalogue475
Year of Publication
2014
Topic
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Author
Kawai, Naohito
Tsuchimoto, Takahiro
Tsuda, Chihiro
Murakam, Satoru
Miura, Sota
Isoda, Hiroshi
Miyake, Tatsuya
Year of Publication
2014
Country of Publication
Canada
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Topic
Mechanical Properties
Keywords
Lateral Load
Opening
Load-Displacement Curves
Shear Performance
Language
English
Conference
World Conference on Timber Engineering
Research Status
Complete
Notes
August 10-14, 2014, Quebec City, Canada
Summary
In this paper, the results of lateral loading tests on two types of CLT shear wall systems with an opening are summarized, one is the shear wall system with assembling narrow size CLT panels and another is that using one large size panel with an opening....
Online Access
Free
Resource Link
Less detail

Study on Seismic Performance of Building Structure with Cross Laminated Timber: Part 12: Objective and Loading Procedure and Accuracy of Static Loading Test

https://research.thinkwood.com/en/permalink/catalogue983
Year of Publication
2013
Topic
Seismic
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems

Failure Analysis of CLT Shear Walls with Opening Subjected to Horizontal and Vertical Loads

https://research.thinkwood.com/en/permalink/catalogue1655
Year of Publication
2016
Topic
Mechanical Properties
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Author
Yasumura, Motoi
Kobayashi, Kenji
Okabe, Minoru
Year of Publication
2016
Country of Publication
Austria
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Topic
Mechanical Properties
Keywords
Opening
FEM
Horizontal Loading
Failure
Language
English
Conference
World Conference on Timber Engineering
Research Status
Complete
Notes
August 22-25, 2016, Vienna, Austria p. 3555-3562
Summary
CLT wall panels having an opening were subjected to horizontal loading and the failure process of CLT around the opening was compared with the simulation by Finite Element Method. Three types of CLT wall panels of 3500mm length and 2700mm height had an opening of 1500mm length and 900mm to 2000mm height at the center of...
Online Access
Free
Resource Link
Less detail

Determination of Seismic Performance Factors for CLT Shear Wall Systems

https://research.thinkwood.com/en/permalink/catalogue770
Year of Publication
2016
Topic
Connections
Seismic
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Author
Amini, M. Omar
van de Lindt, John
Rammer, Douglas
Pei, Shiling
Line, Philip
Popovski, Marjan
Year of Publication
2016
Country of Publication
Austria
Format
Conference Paper
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Topic
Connections
Seismic
Keywords
Angle Bracket
Cyclic Tests
US
Quasi-Static
Seismic Performance Factors
Language
English
Conference
World Conference on Timber Engineering
Research Status
Complete
Notes
August 22-25, 2016, Vienna, Austria
Summary
This paper presents selected results of connector testing and wall testing which were part of a Forest Products Lab-funded project undertaken at Colorado State University in an effort to determine seismic performance factors for cross laminated timber (C...
Online Access
Free
Resource Link
Less detail

Study on Seismic Performance of Building Structure with Cross Laminated Timber: Part 20: Intensity and Performance of Joint

https://research.thinkwood.com/en/permalink/catalogue975
Year of Publication
2013
Topic
Seismic
Connections
Material
CLT (Cross-Laminated Timber)
Application
General Application

Study on Seismic Performance of Building Construction with Cross Laminated Timber: Part 16: Ex Post Fact Analysis for the Static Test of the Full Scale 3-Story Model

https://research.thinkwood.com/en/permalink/catalogue979
Year of Publication
2013
Topic
Seismic
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems

Study on Seismic Performance of Building Construction with Cross Laminated Timber: Part 14: Deformation of Joints and Fracture Behavior on Three Story Full-Scale Static Load Test

https://research.thinkwood.com/en/permalink/catalogue981
Year of Publication
2013
Topic
Seismic
Connections
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems

Study on Seismic Performance of Building Structure with Cross Laminated Timber: Part 13: Relative Story Displacement of Full Scale 3-Story Model -Comparisons with Shaking Table Test

https://research.thinkwood.com/en/permalink/catalogue982
Year of Publication
2013
Topic
Seismic
Material
CLT (Cross-Laminated Timber)
Application
Wood Building Systems

10 records – page 1 of 1.