Skip header and navigation

Refine Results By

10 records – page 1 of 1.

Performance-Based Approach to Support Tall and Large Wood Buildings: Fire and Seismic Performance

https://research.thinkwood.com/en/permalink/catalogue1982
Year of Publication
2017
Topic
Design and Systems
Fire
Seismic
Application
Wood Building Systems
Author
Dagenais, Christian
Chen, Zhiyong
Popovski, Marjan
Organization
FPInnovations
Year of Publication
2017
Country of Publication
Canada
Format
Report
Application
Wood Building Systems
Topic
Design and Systems
Fire
Seismic
Keywords
Performance Based Design
National Building Code of Canada
Language
English
Research Status
Complete
Summary
The objective of the current project is to develop a performance-based design process for wood-based design systems that would meet the objectives and functional statements set forth in the National Building Code of Canada. More specifically, this report discusses the fire and seismic performance of buildings, as identified as a priority in a previous FPInnovations report (Dagenais, C. (2016). Development of Performance Criteria for Wood-Based Building Systems).
Online Access
Free
Resource Link
Less detail

Design Example: Design of Stacked Multi-Storey Wood Shear Walls Using a Mechanics Based Approach

https://research.thinkwood.com/en/permalink/catalogue739
Year of Publication
2013
Topic
Design and Systems
Mechanical Properties
Seismic
Material
Light Frame (Lumber+Panels)
Application
Wood Building Systems
Shear Walls
Author
Newfield, Grant
Ni, Chun
Wang, Jasmine
Organization
Canadian Wood Council
FPInnovations
Year of Publication
2013
Country of Publication
Canada
Format
Report
Material
Light Frame (Lumber+Panels)
Application
Wood Building Systems
Shear Walls
Topic
Design and Systems
Mechanical Properties
Seismic
Keywords
Codes
National Building Code of Canada
Lateral Seismic Loads
Language
English
Research Status
Complete
Summary
Figure 1 shows a floor plan and elevation along with the preliminary shear wall locations for a sixstorey wood-frame building. It is assumed some preliminary calculations have been provided to determine the approximate length of wall required to resist the lateral seismic loads. If the preliminary design could not meet the drift limit requirement using the base shear obtained based on the actual period, the shear walls should be re-designed until the drift limit requirement is satisfied.
Online Access
Free
Resource Link
Less detail

A Mechanics Based Approach for Determining Deflections of Stacked Multi-Storey Wood Based Shear Walls

https://research.thinkwood.com/en/permalink/catalogue738
Year of Publication
2013
Topic
Mechanical Properties
Serviceability
Material
Light Frame (Lumber+Panels)
Application
Wood Building Systems
Shear Walls
Author
Newfield, Grant
Ni, Chun
Wang, Jasmine
Organization
Canadian Wood Council
FPInnovations
Year of Publication
2013
Country of Publication
Canada
Format
Report
Material
Light Frame (Lumber+Panels)
Application
Wood Building Systems
Shear Walls
Topic
Mechanical Properties
Serviceability
Keywords
Multi-Storey
Deflection
Flexural Deformations
Shear
Language
English
Research Status
Complete
Summary
The 2009 edition of CSA Standard O86, Engineering Design in Wood (CSA 2009), provides an equation for determining the deflection of shear walls. It is important to note that this equation only works for a single-storey shear wall with load applied at the top of the wall. While the equation captures the shear and flexural deformations of the shear wall, it does not account for moment at the top of the wall and the cumulative effect due to rotation at the bottom of the wall, which would be expected in a multi-storey structure. In this fact sheet, a mechanics-based method for calculating deflection of a multi-storey wood-based shear wall is presented.
Online Access
Free
Resource Link
Less detail

Advanced Wood-Based Solutions for Mid-Rise and High-Rise Construction: Analytical Models for Balloon-Type CLT Shear Walls

https://research.thinkwood.com/en/permalink/catalogue1877
Year of Publication
2018
Topic
Design and Systems
Material
CLT (Cross-Laminated Timber)
Application
Walls
Author
Chen, Zhiyong
Cuerrier-Auclair, Samuel
Popovski, Marjan
Organization
FPInnovations
Year of Publication
2018
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Application
Walls
Topic
Design and Systems
Keywords
Lateral Loads
Shear
Mass Timber
Language
English
Research Status
Complete
Summary
Lack of research and design information for the seismic performance of balloon-type CLT shear walls prevents CLT from being used as an acceptable solution to resist seismic loads in balloon-type mass-timber buildings. To quantify the performance of balloon-type CLT structures subjected to lateral loads and create the research background for future code implementation of balloon-type CLT systems in CSA O86 and NBCC, FPInnovations initiated a project to determine the behaviour of balloon-type CLT construction. A series of tests on balloon-type CLT walls and connections used in these walls were conducted. Analytical models were developed based on engineering principles and basic mechanics to predict the deflection and resistance of the balloon-type CLT shear walls. This report covers the work related to development of the analytical models and the tests on balloon-type CLT walls that the models were verified against.
Online Access
Free
Resource Link
Less detail

Impact Sound Insulation in Wood Multi-Family Buildings

https://research.thinkwood.com/en/permalink/catalogue2623
Year of Publication
2012
Topic
Acoustics and Vibration
Design and Systems
Material
Light Frame (Lumber+Panels)
Application
Wood Building Systems
Author
Hu, Lin
Organization
FPInnovations
Year of Publication
2012
Format
Report
Material
Light Frame (Lumber+Panels)
Application
Wood Building Systems
Topic
Acoustics and Vibration
Design and Systems
Keywords
Mid-Rise
High-Rise
Sound Transmission
Language
English
Research Status
Complete
Summary
The number of occupant complaints received about annoying low-frequency footstep impact sound transmission through wood floor-ceiling assemblies has been increasing in proportion with the increase in the number of multi-family wood buildings built. Little work has been conducted to develop solutions to control the low-frequency footstep impact sound transmission. There are no code provisions or sound solutions in the codes. Current construction practices are based on a trial and error approach. This two-years project was conducted to remove this barrier and to successfully expand the use of wood in the multi-family and mid- to high-rise building markets. The key objective was to build a framework for the development of thorough solutions to control low-frequency footstep sound transmission through wood floor-ceiling assemblies. Field acoustic tests and case studies were conducted in collaboration with acoustics researchers, builders, developers, architects, design engineers and producers of wood building components. The field study found that: 1. With proper design of the base wood-joisted floors and sound details of the ceiling: With no topping on the floor, the floor-ceiling assembly did not provide sufficient impact sound insulation for low- to high-frequency sound components ; Use of a 13-mm thick wood composite topping along with the ceiling did not ensure satisfactory impact sound insulation; Even if there was the ceiling, use of a 38-mm thick concrete topping without a proper insulation layer to float the topping did not ensure satisfactory impact sound insulation ; A topping system having a mass over 20 kg/m2 and composed of composite panels and an insulation layer with proper thickness achieved satisfactory impact sound insulation. 2. The proper design of the base wood-joisted floors was achieved by the correct combination of floor mass and stiffness. The heaviest wood-joisted floors did not necessarily ensure satisfactory impact insulation. 3. Proper sound ceiling details were found to be achieved through: Use of two layers of gypsum board; Use of sound absorption materials filling at least 50% of the cavity ; Installation of resilient channels to the bottom of the joists through anchoring acoustic system resulted in improved impact sound insulation than directly attaching the resilient channels to the bottom of the joists. A four-task research plan was developed to thoroughly address the issue of poor low-frequency footstep impact insulation of current lightweight wood floor-ceiling assemblies and to correct prejudice against wood. The tasks include: 1) fundamental work to develop code provisions; 2) expansion of FPInnovations’ material testing laboratory to include tests to characterize the acoustic properties of materials; 3) development of control strategies; and 4) implementation. The laboratory acoustic research facility built includes a mock-up field floor-ceiling assembly with adjustable span and room height, a testing system and a building acoustic simulation software. The preliminary study on the effects of flooring, topping and underlayment on FIIC of the mock-up of the filed floor-ceiling assembly in FPInnovations’ acoustic chamber confirmed some findings from the field study. The laboratory study found that: A topping was necessary to ensure the satisfactory impact sound insulation; The topping should be floated on proper underlayment; Topping mass affects impact sound insulation of wood framed floors; A floating flooring enhanced the impact sound insulation of wood framed floors along with the floating topping. It is concluded that: 1. even if the studies only touched the tip of the iceberg of the footstep impact sound insulation of lightweight wood-joisted floor systems, the proposed solutions are promising but still need verification ; 2. with proper design of the base wood floor structure, the proper combination of flooring, and sound ceiling details along with proper installation, the lightweight wood floor-ceiling assembly can achieve satisfactory impact sound insulation ; 3. this study establishes a framework for thoroughly solving low-frequency footstep impact sound insulation problem in lightweight wood-joisted floor systems. Solutions will be developed in the next phase of this study as planned and the study will be conducted under NRCan Transformative Technology program with a project dedicated to “Serviceability of next generation wood building systems”.
Online Access
Free
Resource Link
Less detail

Advanced Wood-Based Solutions for Mid-Rise and High-Rise Construction: Structural Performance of Post-Tensioned CLT Shear Walls with Energy Dissipators

https://research.thinkwood.com/en/permalink/catalogue1472
Year of Publication
2018
Topic
Design and Systems
Mechanical Properties
Seismic
Material
CLT (Cross-Laminated Timber)
Glulam (Glue-Laminated Timber)
LVL (Laminated Veneer Lumber)
LSL (Laminated Strand Lumber)
Application
Shear Walls
Author
Chen, Zhiyong
Popovski, Marjan
Symons, Paul
Organization
FPInnovations
Year of Publication
2018
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Glulam (Glue-Laminated Timber)
LVL (Laminated Veneer Lumber)
LSL (Laminated Strand Lumber)
Application
Shear Walls
Topic
Design and Systems
Mechanical Properties
Seismic
Keywords
Compression Tests
Compression Strength
Energy Dissipation
Post-Tensioned
Pres-Lam
Monotonic Loading
Reverse Cyclic Loading
Language
English
Research Status
Complete
Summary
The latest developments in seismic design philosophy have been geared towards developing of so called "resilient" or "low damage" innovative structural systems that can reduce damage to the structure while offering the same or higher levels of safety to occupants. One such innovative structural system is the Pres-Lam system that is a wood-hybrid system that utilizes post-tensioned (PT) mass timber components in both rigid-frame and wall-based buildings along with various types of energy disspators. To help implement the Pres-Lam system in Canada and the US, information about the system performance made with North American engineered wood products is needed. That information can later be used to develop design guidelines for the designers for wider acceptance of the system by the design community.Several components influence the performance of the Pres-Lam systems: the load-deformation properties of the engineered wood products under compression, load-deformation and energy dissipation properties of the dissipators used, placement of the dissipators in the system, and the level of post-tensioning force. The influence of all these components on the performance of Pres-Lam wall systems under gravity and lateral loads was investigated in this research project. The research project consisted of two main parts: material tests and system tests.
Online Access
Free
Resource Link
Less detail

Advanced Wood-Based Solutions for Mid-Rise and High-Rise Construction: In-Situ Testing of The Arbora Building for Vibration and Acoustic Performances

https://research.thinkwood.com/en/permalink/catalogue1179
Year of Publication
2018
Topic
Acoustics and Vibration
Design and Systems
Material
CLT (Cross-Laminated Timber)
Glulam (Glue-Laminated Timber)
Application
Wood Building Systems
Author
Hu, Lin
Cuerrier-Auclair, Samuel
Organization
FPInnovations
Year of Publication
2018
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Glulam (Glue-Laminated Timber)
Application
Wood Building Systems
Topic
Acoustics and Vibration
Design and Systems
Keywords
Sound Insulation
Tall Wood
Vibration Performance
Mid-Rise
Language
English
Research Status
Complete
Summary
This report addresses serviceability issues of tall wood buildings focusing on vibration and sound insulation performance. The sound insulation and vibration performance may not affect building's safety, but affects occupants' comfort and proper operation of the buildings and the funciton of sensitive equipment, consequently the acceptance of midrise and tall wood buildings in market place. Lack of data, knowledge and experience of sound and vibration performance of tall wood buildings is one of the issues related to design and construction of tall wood buildings.
Online Access
Free
Resource Link
Less detail

Guide for Designing Energy-Efficient Building Enclosures for Wood-Frame Multi-Unit Residential Buildings in Marine to Cold Climate Zones in North America

https://research.thinkwood.com/en/permalink/catalogue2620
Year of Publication
2013
Topic
Energy Performance
Design and Systems
Material
CLT (Cross-Laminated Timber)
Light Frame (Lumber+Panels)
Application
Walls
Author
Finch, Graham
Wang, J.
Ricketts, D.
Organization
FPInnovations
Year of Publication
2013
Country of Publication
Canada
Format
Book/Guide
Material
CLT (Cross-Laminated Timber)
Light Frame (Lumber+Panels)
Application
Walls
Topic
Energy Performance
Design and Systems
Keywords
Thermal Performance
Multi-Family
Residential Buildings
Energy Efficiency
Building Code
Language
English
Research Status
Complete
Summary
The Guide for Designing Energy-Efficient Building Enclosures for Wood-Frame Multi-Unit Residential Buildings in Marine to Cold Climate Zones in North America was developed by FPInnovations in collaboration with RDH Building Engineering Ltd., the Homeowner Protection Office, Branch of BC Housing, and the Canadian Wood Council. The project is part of efforts within the Advanced Building Systems Program of FPInnovations to assemble and add to the knowledge base regarding Canadian wood products and building systems. The team of the Advanced Building Systems Program works with members and partners of FPInnovations to address critical technical issues that threaten existing markets for wood products or which limit expansion or access to such new markets. This guide was developed in response to the rapidly changing energy-efficiency requirements for buildings across Canada and the United States. This guide serves two major objectives: To assist architects, engineers, designers and builders in improving the thermal performance of building enclosures of wood multi-unit residential buildings (MURBs), in response to the increasingly stringent requirements for the energy efficiency of buildings in the marine to cold climate zones in North America (U.S. DOE/ASHRAE and NECB Climate Zones 5 through 7 and parts of Zone 4); To advance MURB design practices, construction practices, and material use based on best knowledge, in order to ensure the durable performance of wood-frame building enclosures that are insulated to higher levels than traditional wood-frame construction. The major requirements for thermal performance of building enclosures are summarized (up to February 2013), including those for the following codes and standards: 2011 National Energy Code of Canada for Buildings (2011 NECB); 2013 interim update of the 2010 National Building Code of Canada (2010 NBC, Section 9.36–Energy Efficiency); 2012 International Energy Conservation Code (2012 IECC); American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard 90.1– Energy Standard for Buildings Except Low-Rise Residential Buildings (2004, 2007, and 2010 versions). In addition to meeting the requirements of the various building codes and standards, a building may need to incorporate construction practices that reflect local preferences in material use, design and construction. Regional climate differences will also affect design solutions. This guide primarily addresses above-grade walls, below-grade walls and roofs of platform wood-frame construction. It also includes information regarding thermal performance of cross-laminated timber (CLT) assemblies as well as the use of non-bearing wood-frame exterior walls (infill walls) in wood post-and-beam and concrete structures. Examples of thermal resistance calculations, building assemblies, critical interface detailing, and appropriate material selection are provided to help guide designers and builders meet the requirements of the various energy-efficiency codes and standards, achieve above-code performance, and ensure long-term durability. This guide builds on the fundamentals of building science and on information contained within the Building Enclosure Design Guide: Wood-Frame Multi-Unit Residential Buildings, published by the Homeowner Protection Office, Branch of BC Housing. This guide is based on the best current knowledge and future updates are anticipated. The guide is not intended to be a substitute for professional advice that considers specific building parameters.
Online Access
Free
Resource Link
Less detail

Advanced Wood-Based Solutions for Mid-Rise and High-Rise Construction: Modelling of Timber Connections Under Force and Fire

https://research.thinkwood.com/en/permalink/catalogue1473
Year of Publication
2018
Topic
Connections
Fire
Seismic
Design and Systems
Material
LVL (Laminated Veneer Lumber)
Glulam (Glue-Laminated Timber)
Application
Beams
Author
Chen, Zhiyong
Ni, Chun
Dagenais, Christian
Organization
FPInnovations
Year of Publication
2018
Country of Publication
Canada
Format
Report
Material
LVL (Laminated Veneer Lumber)
Glulam (Glue-Laminated Timber)
Application
Beams
Topic
Connections
Fire
Seismic
Design and Systems
Keywords
Finite Element Model
Bolted Connection
Load-Displacement Curves
Language
English
Research Status
Complete
Summary
FPInnovations carried out a survey with consultants and researchers on the use of analytical models and software packages related to the analysis and design of mass timber buildings. The responses confirmed that a lack of suitable models and related information for material properties of timber connections was creating an impediment to the design and construction of this type of buildings. Furthermore, there is currently a lack of computer models and expertise for carrying out performance-based design for wood buildings, in particular seismic and/or fire performance design. In this study, a sophisticated constitutive model for wood-based composite material under stress and temperature was developed. This constitutive model was programmed into a user-subroutine which can be added to most general-purpose finite element software. The developed model was validated with test results of a laminated veneer lumber (LVL) beam and glulam bolted connection under force and/or fire.
Online Access
Free
Resource Link
Less detail

Design Models for CLT Shearwalls and Assemblies Based on Connection Properties

https://research.thinkwood.com/en/permalink/catalogue369
Year of Publication
2014
Topic
Connections
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Author
Popovski, Marjan
Gavric, Igor
Organization
FPInnovations
Year of Publication
2014
Country of Publication
Canada
Format
Report
Material
CLT (Cross-Laminated Timber)
Application
Shear Walls
Topic
Connections
Keywords
Lateral Loads
Analytical Model
North America
Europe
Language
English
Research Status
Complete
Summary
The work presented in this report is a continuation of the FPInnovations' research project on determining the performance of the CLT as a structural system under lateral loads. As currently there are no standardized methods for determining the resistance of CLT shearwalls under lateral loads, the design approaches are left at the descretion of the designers. The most common approach that is currently used in Europe and North America assumes that the resistance of CLT walls is a simple summary of the shear resistance of all connectors at the bottom of the wall. In this report some new analytical models for predicting the design (factored) resistance of CLT walls under lateral loads were developed based on connection properties. These new models were then evaluated for their consistency along with their models that are currently used in North America and in Europe.
Online Access
Free
Resource Link
Less detail

10 records – page 1 of 1.